Chapter 3

Compression members

Buckling resistance depends on length, restraint, axis, fabrication and local plate slenderness. A large area does not ensure a large compression capacity. Built-up columns also need enough transverse stiffness to make their components act together.

3.1 Effective length and governing axis

End conditions in the buckling planeIdeal elastic KeK_eIS 800 design recommendation
Both ends pinned, translations restrained1.01.0
Both ends fixed, no relative translation0.50.65
One fixed, one pinned, no relative translationabout 0.6990.8
Fixed–free cantilever2.02.0
Rotations restrained at both ends; relative lateral translation free1.01.2

These ideal factors require the stated restraints. Frame columns may need frame-specific effective lengths. Use a question's explicit value in an ideal buckling problem. Compute each axis separately; the axis with the smallest radius need not govern if effective lengths or buckling classes differ.

Compression conditionMaximum λs\lambda_s
Dead and imposed load compression180
Compression only with wind/earthquake combination, subject to the code's deformation condition250
Beam compression flange restrained against lateral-torsional buckling300

3.2 Design buckling stress

Common sectionConditionMajor z−zz-z classMinor y−yy-y class
Rolled Ih/bf>1.2h/b_f>1.2, tf≤40t_f\le40 mmab
Rolled Ih/bf>1.2h/b_f>1.2, 40<tf≤10040<t_f\le100 mmbc
Rolled Ih/bf≤1.2h/b_f\le1.2, tf≤100t_f\le100 mmbc
Rolled Ih/bf≤1.2h/b_f\le1.2, tf>100t_f>100 mmdd
Welded Itf≤40t_f\le40 mmbc
Welded Itf>40t_f>40 mmcd
Hot-rolled hollow sectionAny axisaa
Channel, angle, T, solid section; built-up memberOrdinary concentric bucklingcc

h,bf,tfh,b_f,t_f are overall depth, flange width and flange thickness. Use the appropriate complete code entry for a section outside these common cases; the one-leg angle model below has its own curve.

3.3 Angles connected through one leg

Concentric angle compression uses the ordinary buckling calculation. A one-leg connection introduces eccentricity and flexural-torsional effects; it is not a concentric column merely because the external force is labelled axial.

For discontinuous double angles on opposite sides of a gusset, connected by at least two in-line bolts at each end or equivalent welding, take in-plane effective length as 0.7–0.85 times the node spacing according to restraint, and out-of-plane length as the node spacing. Double angles on the same side retain eccentricity; do not use the opposite-side simplification.

3.4 Laced built-up columns

Use 40∘≤θ≤70∘40^\circ\le\theta\le70^\circ. Limit lacing-bar slenderness to 145. A flat lacing bar needs thickness at least its effective length/40 for single lacing or effective length/60 for double lacing. For bolted single lacing, effective length is the distance between inner end fasteners; double lacing connected at intersections may use 0.7 of that length. For welded lacing use 0.7 times the distance between inner ends of the welds. The flat's width is at least three nominal bolt diameters at a bolted end.

Check diagonal compression with its own radius and buckling curve, tension with the tension rules, and its end fasteners. Add calculated transverse shear to the notional shear when present. Provide tie plates at ends and interruptions. Merely crossing two bars does not create a supported intersection.

3.5 Battened built-up columns

Provide at least three longitudinal bays. End battens and battens at restraints need effective depth at least the distance between main-component centroids; intermediate battens need at least three quarters of it. Every batten also needs effective depth at least twice the main component width in that plane. Effective depth is measured between outermost end fasteners/welds. Plate thickness must be at least the clear distance between the innermost transverse connecting lines divided by 50.

The 1.10 simplification is for the code's ordinary battened-column conditions. Eccentric loading, applied moments or lateral loads in the batten plane require the additional elastic-stability treatment; the notional shear alone is insufficient.

Last-minute recall

  • Calculate effective lengths and buckling classes for both axes.
  • Ideal fixed–fixed length is 0.5L0.5L; the ordinary code design recommendation is 0.65L0.65L.
  • Use AefcdA_ef_{cd}, not Euler load, as the code compression resistance.
  • One-leg angle compression has a revised 2024 model.
  • Increase whole-column slenderness by 5% for lacing and 10% for battens.
  • Design the transverse system for at least 2.5% of axial force.
  • Batten end bolts carry a moment as well as shear.
  • Check component slenderness between transverse connections.

Revise offline: the whole Steel Structures handbook as one PDF

49 pages · 1.9 MBFree to read online. Sign in to download the PDF.We save the handbook, version and request time in My downloads. Privacy policy

All chapters · Corrections