Tension members
Tension resistance is controlled by the weakest available load path. Gross yielding concerns the whole member; fracture and block shear concern the connection region. An unconnected leg does not immediately develop the same stress as the connected leg.
2.1 Gross yielding and net rupture
2.2 Straight and staggered net sections
For angles, unfold the legs into a developed path; include the corner geometry when finding the gauge across different legs. For threaded rods use the root section rather than nominal shank area. Where holes are directly punched, IS 800's net-area provision adds 2 mm to the actual hole size for the deduction; do not confuse that allowance with the standard bolt-hole clearance.
Two competing paths through a staggered plate connection; dimensions refer to hole centres.
2.3 Shear lag in a connected angle
Longer connections reduce shear lag. For other partly connected rolled sections, use the corresponding connected and outstanding areas and the actual shear-lag distance. The gross-yield and block-shear checks still apply.
A lug angle provides another load path into an outstanding leg. For an angle main member, the lug and its gusset connection resist at least 1.2 times the force assigned to that leg; its connection to the main angle resists at least 1.4 times that force. For a channel's outstanding portion, the corresponding factors are 1.1 and 1.2. Provide at least two bolts or equivalent weld at the lug-to-gusset connection. Check net sections after adding the lug.
2.4 Block shear and tension detailing
Draw the block before subtracting holes. A hole cut completely along a shear path removes a full diameter; a path ending at a hole centre removes half a diameter at that end. Include both shear planes when the block has two. For a welded end connection, locate the block around the weld group; absence of holes does not remove block shear as a possible mode.
| Member condition | Maximum effective slenderness |
|---|---|
| Stress reversal from actions other than wind/earthquake | 180 |
| Normally a tie, possible wind/earthquake reversal; compression not credited | 350 |
| Member always in tension | 400 |
is the applicable effective length and radius of gyration (same length unit). If compression resistance is required, use the compression rules as well. Splice plates and each side of a tension splice must transmit the design force; two ends of a splice act in series, not as two capacities to add.
Last-minute recall
- Tension resistance is the minimum of three member modes plus the connection check.
- Gross area is for yielding; critical net area is for rupture.
- Search straight and staggered cuts.
- Shear lag is caused by incomplete cross-section connection.
- The corrected shear-lag cap contains 0.9.
- Draw every block and account for half holes at its corners.
- A tie that must resist reversed compression needs a compression check.