Voltage-source and current-source inverters
An inverter controls an AC output from a DC link. A voltage-source inverter (VSI) imposes voltage and lets the load set current; a current-source inverter (CSI) imposes current and lets the load set voltage. Commutation paths must match the link's stored energy.
7.1 Single-phase bridge voltage and spectrum
Past papers · EE 2020–2026 (7 papers): 1 question, 2 marks
Let be total DC-link voltage. A half bridge uses a split link and applies relative to its midpoint. A full bridge applies with one diagonal pair and with the other. Both upper switches, or both lower switches, give a zero full-bridge output state. The two devices in any one VSI leg must never simultaneously short the DC link.
With inductive loading, current may oppose applied voltage. Antiparallel diodes or reverse-conducting MOSFET channels return energy to the DC link. A DC supply unable to absorb that energy needs a suitable storage or dissipation path. Insert dead time to prevent leg shoot-through; during dead time the current polarity determines which diode clamps the pole.
7.2 Inductive current and device RMS
Past papers · EE 2020–2026 (7 papers): 2 questions, 4 marks
Use the actual device's conducting intervals, including any reverse channel conduction. A gate-on MOSFET can carry negative channel current; an IGBT cannot, and its antiparallel diode then carries the load current.
7.3 Quasi-square voltage and selective harmonic cancellation
Past papers · EE 2020–2026 (7 papers): 2 questions, 3 marks
Define a symmetric three-level waveform: zero on , on , and zero up to . Repeat with opposite sign in the next half-cycle. The notch angle is ; the nonzero pulse width per half-cycle is .
7.4 Three-phase six-step voltage-source inverter
For a two-level bridge, let specify the upper switch on in each leg; the lower switch is complementary. Pole voltages relative to the negative rail are and similarly for b and c. With a balanced star load and floating neutral, . Thus and .
7.5 Sinusoidal pulse-width modulation
Past papers · EE 2020–2026 (7 papers): 1 question, 2 marks
Compare a sinusoidal reference of peak with a symmetric triangular carrier of peak . The amplitude ratio sets fundamental voltage; is carrier frequency divided by desired output frequency. Use peak-to-peak values in both numerator and denominator only if both are converted consistently.
The carrier sets the switching-ripple scale, not the fundamental frequency. Harmonics lie around carrier groups and their sidebands; symmetry and line subtraction remove some components. Exact amplitudes require the specified modulation and carrier ratio. For synchronous PWM, odd integer helps half-wave symmetry; odd multiples of three are commonly used for balanced three-phase symmetry. For , reference clipping gives overmodulation and the linear gain table no longer holds. The six-step limit is in Section 7.4.
Sine–triangle comparison and a bipolar full-bridge output over one fundamental period.
7.6 Single-phase and three-phase current-source inverters
A CSI has a stiff DC current , usually maintained by a large series DC-link inductor. It must always provide a path for that current. Brief commutation overlap can be necessary; opening all paths is dangerous. Its switches need forward-current conduction and reverse-voltage blocking, often obtained with a series diode. A VSI instead needs a reverse-current path and must avoid leg shoot-through.
In a three-phase CSI, one upper and one lower switch normally conduct, routing DC current into one phase and out of another. Thyristor CSIs require forced or load commutation; capacitors can supply the temporary reverse voltage and carry current during transfer. In PWM current-source operation, active states route link current between phases, while zero states circulate it within the converter. Averaging dwell times shapes the fundamental current. Never import a VSI voltage-gain formula into a CSI.
Last-minute recall
- A half bridge uses half the total link voltage at its output.
- Dead time prevents a VSI leg from shorting its link.
- A CSI must retain a DC-current path during transfer.
- Inductive load current can flow opposite to the commanded voltage.
- Square voltage drives triangular current in an ideal pure inductor.
- Quasi-square notch angle and SPWM amplitude ratio are different controls.
- Three-phase pole voltage differs from load phase voltage.
- SPWM phase fundamental peak is .
- Use the specified device reverse-current model for RMS ratings.