Chapter 6

Forced commutation of thyristors

A DC source has no natural current zero to turn off an SCR. An auxiliary circuit must first remove the main-device current, then hold the device reverse biased long enough for recovery. Follow capacitor polarity throughout the commutation sequence.

6.1 Capacitor voltage commutation

Past papers · EE 2020–2026 (7 papers): 1 question, 1 mark

A precharged capacitor can apply reverse voltage across a conducting SCR when an auxiliary SCR is fired. The load current then charges or discharges the capacitor. The useful recovery interval ends when the main SCR voltage first becomes forward biased, not necessarily when the complete commutation sequence ends.

The capacitor must be recharged to the correct polarity before the next turn-off command. Check the auxiliary SCR's own current zero and recovery, as well as the main SCR. A commutation inductor can reverse capacitor polarity resonantly, but the exact reset interval depends on the diode and source connections.

6.2 Resonant current commutation

Past papers · EE 2020–2026 (7 papers): 1 question, 2 marks

An auxiliary LC branch injects a current opposite to the main SCR current. The main current becomes zero when the injected current first reaches the load current. If an antiparallel path clamps the main SCR, the excess resonant current can maintain the required reverse bias until the second intersection.

Two current intersections delimit the counter-current recovery window; the voltage-commutation panel shows a separate capacitor discharge.Two current intersections delimit the counter-current recovery window; the voltage-commutation panel shows a separate capacitor discharge.

6.3 Natural current zero in a resonant load

A series RLC path can make its SCR current return to zero even with a DC source. This is load commutation. Determine the capacitor's initial voltage from the preceding state; its sign can assist or oppose the source.

Last-minute recall

  • Device recovery time tqt_q and circuit-provided time tct_c are different quantities.
  • Use the capacitor voltage actually applied across the SCR.
  • Constant-current capacitor discharge gives a linear voltage ramp.
  • Resonant peak current must exceed the load current.
  • Verify reverse bias during the entire claimed recovery window.
  • Include capacitor reset and auxiliary-device recovery before another cycle.
  • A damped resonant pulse peaks before its undamped quarter-cycle.