Line-current harmonics and power factor
Always identify the source-voltage reference before assigning harmonic phase. Harmonic amplitudes determine heating; only matching voltage and current harmonics contribute to average active power.
5.1 Harmonic convention and power definitions
Past papers · EE 2020–2026 (7 papers): 2 questions, 2 marks
Write a current using signed sine and cosine coefficients relative to : . Here is DC current, harmonic order and are peak coefficients (A). A positive in denotes lag relative to , with .
Use for distortion factor and DPF for displacement factor; the abbreviation DF is ambiguous across books. Signed PF is negative for exported active power with current defined into the converter. If only its magnitude is requested, state the power-flow direction separately.
5.2 Single-phase bridge line-current spectrum
Past papers · EE 2020–2026 (7 papers): 1 question, 1 mark
Assume a full diode or full SCR bridge with constant positive DC current , no source inductance and no freewheel interval. With the phase convention of Section 4.1, line current is a square wave delayed by . For a diode bridge set .
For a full SCR bridge operating as a line inverter, but : it exports active power while still drawing fundamental reactive power. Commutation overlap rounds current transitions and changes both magnitudes and phases; do not apply the zero-overlap spectrum unchanged.
5.3 Semiconverter current spectrum
Past papers · EE 2020–2026 (7 papers): 2 questions, 4 marks
Use constant current and the line-current intervals in Section 4.2. The pulse width is , centred at in the positive half-cycle. That centre, rather than just the first edge, sets the fundamental phase.
5.4 Three-phase line-current spectrum
For the six-pulse full bridge, let and define from natural commutation. At , phase-a line current equals from to , equals from to , and is zero elsewhere. Delayed firing translates this waveform by in the ideal no-overlap, constant-current case.
Last-minute recall
- State the phase-voltage reference before giving harmonic phase.
- A negative Fourier coefficient adds to a positive-magnitude representation.
- Source-current harmonics and output-voltage ripple occur at different orders.
- PF equals distortion factor times displacement factor only for sinusoidal supply voltage.
- The usual THD-to-distortion relation excludes DC current.
- Full single-phase bridges give odd current harmonics under constant-current loading.
- Balanced six-pulse bridges give line harmonics.
- A line-commutated inverter still consumes fundamental reactive power.