Chapter 4

Line-commutated thyristor converters

Firing angle delays transfer from one source path to the next. The familiar cosine law requires continuous current; a resistive load or an extinguished load current produces different intervals and a different average.

4.1 Single-phase controlled rectification

Let vs=Vmsin⁡θv_s=V_m\sin\theta, Vs=Vm/2V_s=V_m/\sqrt2, and measure α\alpha from the positive zero crossing for the first pair. A full bridge fires alternate diagonal SCR pairs at α\alpha and π+α\pi+\alpha. In CCM each pair conducts for π\pi radians, including a negative-voltage interval when α>0\alpha>0.

4.2 Half-controlled bridge and freewheeling

Past papers · EE 2020–2026 (7 papers): 1 question, 2 marks

A single-phase semiconverter uses two SCRs and two diodes. Its freewheel intervals remove the negative output-voltage portions. With positive continuous load current, it is a one-quadrant converter: Vo≥0V_o\ge0, Io≥0I_o\ge0. A full SCR bridge with an external freewheel diode gives the same ideal output voltage, though individual device currents need not be the same.

Device current depends on where the SCRs are placed. With both SCRs in the upper bridge group and both diodes in the lower group, each device conducts for 180∘180^\circ in ideal continuous current, including internal freewheeling. With both SCRs in one AC-side leg and both diodes in the other, each SCR conducts for π−α\pi-\alpha and each diode for π+α\pi+\alpha. Obtain average and RMS currents from these intervals; an external freewheel diode can change them again.

For nonstandard mixed bridges, write the conducting source pair and output voltage in each interval. A topology containing three SCRs and one diode is not automatically a standard semiconverter. Its firing sequence and freewheel paths decide its average output.

4.3 Three-phase controlled converters

Past papers · EE 2020–2026 (7 papers): 1 question, 2 marks

Use VmpV_{mp} for phase peak and Vml=3VmpV_{ml}=\sqrt3V_{mp} for line peak. Firing delay α\alpha is measured from the natural commutation instant, not automatically from a phase-voltage zero. Upper devices are fired 120∘120^\circ apart; successive bridge commutations occur every 60∘60^\circ. At startup, bridge firing may require a pulse pair or repeated pulses so both devices of a path are available.

4.4 Source inductance and overlap

Past papers · EE 2020–2026 (7 papers): 1 question, 2 marks

Source inductance prevents an instantaneous current transfer. During overlap both outgoing and incoming paths conduct, reducing average DC voltage. Let μ\mu be overlap angle. The formulas below assume constant Io>0I_o>0, ideal devices, sinusoidal source voltage and no simultaneous overlap between successive commutations.

4.5 Rectification, regeneration and dual converters

Past papers · EE 2020–2026 (7 papers): 1 question, 2 marks

Choose positive DC current out of the bridge's positive reference terminal and keep that direction fixed. For a load represented by R,LR,L and signed emf EE, average voltage is Vo=E+RIoV_o=E+RI_o. The bridge cannot reverse its SCR current; inversion instead reverses average DC voltage, with a DC source maintaining positive current.

A noncirculating dual converter enables one bridge at a time and waits for current extinction before transferring control. A semiconverter cannot regenerate into the AC supply. In motor braking problems, obtain the speed-dependent emf from the Electrical Machines handbook and then assign its sign using the actual armature connection.

Last-minute recall

  • Firing angle needs an explicit reference instant.
  • The cosine law needs continuous current.
  • A semiconverter freewheels and cannot produce negative average DC voltage.
  • For an unusual bridge, reconstruct intervals rather than naming it by device count.
  • Source inductance produces overlap and lowers average output voltage.
  • Single-phase total loop inductance differs from three-phase per-phase inductance.
  • Inversion needs a DC energy source and sufficient extinction margin.
  • SCR bridge current keeps its direction when average voltage reverses.

Revise offline: the whole Power Electronics handbook as one PDF

47 pages · 2.1 MBFree to read online. Sign in to download the PDF.We save the handbook, version and request time in My downloads. Privacy policy

All chapters · Corrections