Uncontrolled rectifiers and load conduction
Diodes select the available source polarity without a firing command. Output-voltage averages can often be found from symmetry, but source current depends strongly on whether the load is resistive, inductively smoothed or capacitor fed.
3.1 Single-phase diode configurations
Past papers · EE 2020–2026 (7 papers): 1 question, 1 mark
Let , with , source peak (V) and source RMS . A bridge uses four diodes; two conduct at once. A centre-tapped full-wave circuit uses two diodes and one half of the secondary at a time. For the centre-tapped row below, is the peak of one half-secondary, not the end-to-end peak.
For a bridge with an R load, source current is , so the input power factor is unity. For a bridge with large smoothing inductance and almost constant current, source current is square and its power factor is below unity even though its fundamental is in phase with the voltage. A half-wave R load has source-current DC content and power factor .
3.2 Three-phase diode configurations
Use a balanced positive-sequence supply: , and . Define phase RMS , line RMS and line peak .
A three-diode neutral-return rectifier selects the most positive phase. A six-diode bridge selects the most positive phase for its upper diode and the most negative phase for its lower diode: . Each diode conducts for ; each bridge pair persists for .
The three-pulse circuit needs a neutral return and has DC current in each phase winding. The six-pulse bridge needs no neutral and has no DC component in each AC line current. For R loading, calculate instantaneous line current from the selected line voltage divided by ; do not use constant- current tables.
Source-current pulses for a six-pulse bridge and the phase-voltage reference.
3.3 Natural extinction with RL and emf loads
Past papers · EE 2020–2026 (7 papers): 5 questions, 7 marks
The following equations determine conduction limits for one conducting source path. They also apply to an SCR path once firing has established conduction. Let , let positive load current flow through and opposing emf , and suppose conduction starts at with current . The extinction angle is the next physically valid current zero; a diode or SCR cannot continue into negative current.
A freewheel diode across an RL load carries current when the source path becomes reverse biased and clamps ideal output voltage to zero. During freewheeling with , the current decays as . With an opposing emf, use the interval equation of Section 2.6 with applied voltage zero and stop at current zero.
For a bidirectional thyristor AC controller feeding an RL load, the boundary between full conduction and useful phase control is under symmetric sustained gating; for , conduction is discontinuous. This is a gating/conduction application of the same RL equation, not a separate AC-controller formula set.
3.4 Capacitor-input loading and rectifier assumptions
An output capacitor changes diode conduction: the diodes carry narrow charging pulses near voltage maxima instead of a square or rectangular current. Without source resistance/inductance, an initially uncharged ideal capacitor can imply an impulse current. The rectifier's average output then approaches the source peak, not the unfiltered rectified average.
Last-minute recall
- A bridge uses line/source peak for PIV; a centre-tapped diode sees twice its half-winding peak.
- R-load power uses RMS output voltage.
- Source current is sinusoidal for an ideal single-phase R-loaded bridge.
- A capacitor-input bridge does not draw rectangular current.
- A six-pulse bridge selects maximum phase minus minimum phase.
- Device current ratings depend on load-current shape.
- Inductance extends conduction beyond the source voltage zero.
- With an emf load, first determine when the source can forward-bias the diode.