DC–DC conversion
Start by drawing the current path in each switching interval. Volt-second balance and capacitor charge balance give the DC operating point; slopes and interval lengths then give ripple and device stress.
2.1 Switching balance and current bookkeeping
Past papers · EE 2020–2026 (7 papers): 2 questions, 4 marks
Use for input DC voltage, for signed output voltage, for positive resistive-load current magnitude, for duty ratio and for switching period. Unless stated otherwise, assume ideal components, steady state and small output-voltage ripple. Continuous conduction mode (CCM) means the inductor current never reaches zero; at the boundary it just touches zero. A diode prevents the current from becoming negative in discontinuous conduction mode (DCM).
For startup or a transient, do not impose zero volt-seconds. Instead update over each cycle, changing the topology if a diode current reaches zero. For a constant-current load, calculate power from its current times its average terminal voltage. Arbitrary gate sequences require the actual overlap of gate intervals, not the sum of individual duty ratios.
2.2 Buck converter
Past papers · EE 2020–2026 (7 papers): 1 question, 2 marks
The conventional buck has a series switch from input to a switching node, a freewheel diode from ground to that node, and an inductor from that node to the positive output. During on-time the switch supplies the inductor; during off-time the diode carries it. The output capacitor is across the load.
2.3 Boost converter
Past papers · EE 2020–2026 (7 papers): 1 question, 2 marks
The conventional boost places the inductor between input and switching node, the switch from node to ground, and the diode from node to positive output. On-time stores energy in the inductor while the capacitor supplies the load. Off-time transfers source and inductor energy to the output.
2.4 Inverting buck–boost converter
Past papers · EE 2020–2026 (7 papers): 2 questions, 4 marks
The conventional single-switch buck–boost charges its inductor from the positive input during on-time. During off-time the inductor discharges through a diode into a capacitor whose output terminal is negative relative to input return. Define and positive load-current magnitude .
Inductor voltage and current for the three conventional converters, using one operating point per topology.
2.5 Discontinuous conduction and boundary operation
Past papers · EE 2020–2026 (7 papers): 1 question, 2 marks
DCM has three intervals: switch on for , diode on for , then zero inductor current for . With small output ripple and a resistor load, define the dimensionless parameter and positive conversion ratio .
2.6 Reading unfamiliar switching circuits
Past papers · EE 2020–2026 (7 papers): 2 questions, 2 marks
For each gate interval, first replace on switches by shorts and off switches by opens. Then test diode polarity using inductor-current continuity and capacitor-voltage continuity. Write KVL for , KCL for , and the terminal voltage or current asked for. Repeat at every switching or natural current-zero event. An assumed diode state is acceptable only if its current and blocking polarity agree with that assumption.
Do not use a steady-state voltage ratio to solve a specified finite-cycle startup. Do not use the average terminal voltage to calculate resistor power unless its current is constant: resistor heating uses RMS current. This method also handles a source-current chopper with unusual gate overlap without needing a memorised topology name.
Last-minute recall
- Volt-second balance is a steady-state condition.
- Buck inductor mean current equals load mean current.
- Boost inductor mean current equals source mean current.
- Buck–boost output polarity is negative in the conventional topology.
- State whether a quoted output is signed voltage or magnitude.
- Ripple is peak-to-peak; peak current is mean plus half the ripple.
- Check the conduction mode before choosing a gain formula.
- Device RMS currents include zero-current off intervals.
- In DCM, find the diode interval as well as the switch interval.