Chapter 8

Bidirectional AC–DC voltage-source converters

A self-commutated bridge with a capacitive DC link can exchange active power in either direction while controlling AC current phase. Its DC polarity stays fixed; the mean DC current reverses with power flow. An AC-side inductor makes current controllable by the bridge voltage.

8.1 AC-side voltage and power-flow signs

Use RMS fundamental phasors and define I‾\underline I positive from converter to grid. Let grid phase voltage be V‾g=Vg∠0\underline V_g=V_g\angle0 and converter phase voltage V‾c=Vc∠δ\underline V_c=V_c\angle\delta. The coupling impedance is Rg+jXgR_g+jX_g, with Xg=ωLgX_g=\omega L_g. This section's export-positive current differs from the rectifier input-current convention in Chapter 5.

At unity grid power factor, set Qg=0Q_g=0, not necessarily Qc=0Q_c=0. In export operation, current is in phase with grid voltage; in rectification it is in antiphase under the chosen outward current arrow. A synchronised current controller sets current amplitude and phase; an outer DC-voltage controller adjusts active-current demand. Controller design belongs in the Control Systems handbook.

8.2 Modulation range and apparent power

Past papers · EE 2020–2026 (7 papers): 1 question, 2 marks

The fundamental voltage needed by the inductor equation must fit within the bridge's modulation range. Use the voltage at the converter terminals for this check. Grid voltage alone omits the coupling-impedance drop.

For a conventional three-phase bridge, antiparallel diodes form an uncontrolled rectifier when gates are off. A DC link below the rectified line-voltage peak can admit uncontrolled charging current. This diode-conduction threshold differs from the higher fundamental-voltage bound of plain sinusoidal PWM. Precharge and current limiting establish the link safely before closed-loop operation.

Define Pdc,inP_{\rm dc,in} positive from the DC source into the link and Pac,outP_{\rm ac,out} positive exported at the converter AC terminals. A capacitor temporarily absorbs any power imbalance. A balanced three-phase sinusoidal system has constant total instantaneous power; a single-phase system generally has a double-frequency component.

Last-minute recall

  • State the current arrow before assigning active and reactive power signs.
  • Converter-terminal and grid-terminal complex powers differ across the coupling impedance.
  • A PWM rectifier can control current phase and return energy to the grid.
  • Use converter voltage, not grid voltage alone, to calculate modulation amplitude.
  • SPWM headroom and diode uncontrolled-charging thresholds are different limits.
  • Capacitor energy changes according to net instantaneous power.
  • Single-phase link ripple occurs at twice the fundamental frequency.
  • Balanced three-phase sinusoidal power has no double-frequency total-power ripple.