Tolerance analysis in assembly

Write a signed dimension loop before inserting numbers. Worst-case analysis guarantees every permitted combination; statistical analysis predicts spread under distribution and correlation assumptions. Selective assembly changes which combinations are allowed.

8.1 Signed loops and worst-case limits

Choose the positive assembly direction. Express the closing gap, length or interference as a sum of directed dimensions. Convert unilateral limits to their midpoints and half-widths if using symmetric notation. A term subtracted in the nominal loop still contributes a positive amount to the worst-case tolerance width.

For a nonlinear chain Y=f(X1,…,Xn)Y=f(X_1,\ldots,X_n) with small deviations, a first-order worst-case bound is the sum of ∣∂f/∂Xi∣τi|\partial f/\partial X_i|\tau_i. Check actual extrema if the function is nonmonotonic or deviations are not small. The “tolerance sink” is the closing dimension that receives the accumulated variation.

8.2 Statistical stacks and correlation

Random assembly does not imply that all dimensional errors have the same distribution. Use means and standard deviations when supplied. Root-sum-square tolerances are meaningful only after relating the tolerance bands to a common statistical coverage.

For independent uniform deviations within ±τi\pm\tau_i, the variance of each input is τi2/3\tau_i^2/3, not τi2/9\tau_i^2/9. Shared temperature, common setups and paired machining can introduce correlation. For a difference of strongly positively correlated dimensions, some common error cancels.

8.3 Allocation and selective assembly

Allocate tolerance to manufacturable dimensions while keeping the closing requirement. Equal allocation is a calculation assumption, not generally the lowest-cost choice. For manufacturing quality and capability concepts, see the Production Planning and Control handbook.

In selective assembly, measure and sort parts, then pair compatible groups. Narrow bins reduce the clearance spread within each pair even when total production spreads are wider. This sacrifices unrestricted interchangeability and needs adequate numbers in matching bins. Equal-width bins do not by themselves guarantee a target clearance; their relative locations matter.

Last-minute recall

  • Close the directed dimension loop before combining tolerances.
  • Midpoint plus/minus half-width can represent any two finite limits.
  • Worst-case half-widths add with absolute sensitivity coefficients.
  • Subtraction of dimensions does not subtract their worst-case tolerance widths.
  • Variances add only after covariance terms are handled.
  • RSS limits are statistical coverage bands, not guaranteed bounds.
  • Selective assembly restricts combinations; it does not improve each part's accuracy.