Chapter 7

Alignment, testing and coordinate measurement

A measurement must be tied to the same datum system as the requirement. Machine-tool tests distinguish geometry from behaviour under load. A CMM acquires spatial coordinates and fits features; the chosen fit and datum constraints determine the reported dimension.

7.1 Machine-tool alignment and acceptance tests

TestTypical setupWhat to separate
Bed/slide straightnessLevel or autocollimator along repeated stationsSurface slope versus accumulated height
Spindle radial runoutIndicator on a suitable test mandrel near and away from spindleEccentricity, angular misalignment, mandrel error
Spindle axial runoutAxial indicator on a reference faceFace wobble versus axial motion
Spindle-axis parallelism to slideTraverse indicator along a test mandrel in two planesVertical and horizontal errors
Slide squarenessPrecision square with indicator, or optical squareIndividual straightness and mutual axis angle
Table flatnessGrid survey with indicator/level/autocollimatorDatum-plane choice and local form
Positioning and reversalCalibrated scale or laser interferometer, both directionsScale/pitch error, backlash, repeatability
Cutting testMachine a specified test piece, inspect itDeflection, vibration and thermal effects under working conditions

Level a machine as specified before geometric tests; a twisted support can change the measured geometry. A no-load geometric test does not establish cutting accuracy. Repeat selected tests after thermal stabilisation. Do not assign acceptance tolerances without the applicable specification.

7.2 Straightness from slope readings

A level or autocollimator with a two-foot base measures slope across its base. Move it by the base length to obtain contiguous segments. Integrate those slopes to build height, then remove the chosen reference line. Angle measurements alone do not fix the initial height.

The range of zk′z'_k is straightness relative to the endpoint line, not automatically the minimum-zone value. For a surface grid, combine intersecting traverses consistently and remove a plane; a single line survey cannot establish full-surface flatness. This slope-to-height method is also described in the IIT Kharagpur metrology laboratory.

7.3 CMM hardware, datums and probe compensation

A coordinate measuring machine combines three measured axes, a probe, a stable structure and software. Bridge, cantilever, gantry and horizontal-arm arrangements trade access, part size and stiffness. Touch-trigger probes capture discrete points; scanning probes acquire a continuous sequence; optical sensors acquire points without contact.

Before inspection: qualify the stylus, measure datum features, establish the part coordinate system, then probe the required features. Probe qualification on a reference artefact determines effective stylus size and offsets and compensates repeatable pretravel; it is not a complete calibration of the CMM structure. See probe operation and qualification.

Ideal featureMinimum nondegenerate point data
LineTwo distinct points
PlaneThree non-collinear points
Circle in a known planeThree non-collinear points
SphereFour non-coplanar points

These are mathematical minima, not adequate sampling plans for every real part. Spread more points over the full feature to detect form error. For a rectangular datum system, the primary plane removes three rigid-body freedoms, a secondary perpendicular datum two, and a tertiary datum the last one. The software coordinate system follows these constraints, not the arbitrary placement on the CMM table.

7.4 Fitted planes and datum-normal distance

Past papers · ME 2020–2026 (10 papers): 1 question, 2 marks

State the fitting rule before calculating a distance. Two independently fitted nonparallel infinite planes intersect, so they do not have one constant positive separation. A datum-normal size can instead constrain the second fitted plane parallel to the datum, or specify where the distance is evaluated.

For an orthogonal least-squares plane, compute the point centroid and the unit eigenvector corresponding to the smallest eigenvalue of the centred coordinate scatter matrix; that vector is the plane normal. This minimises perpendicular squared distances, unlike vertical regression. The centroid lies on the fitted plane. When fitting a second plane with the datum normal held fixed, its offset is the mean projection of its measured points onto that normal. Feature-fitting software distinguishes least-squares and envelope fits; see the CMM fitting-algorithm guide.

The shortest separation is along the datum normal, not the vertical coordinate direction.The shortest separation is along the datum normal, not the vertical coordinate direction.

Last-minute recall

  • Geometric machine tests and loaded cutting tests answer different questions.
  • A test mandrel can carry its own errors; reversal or rotation helps separate them.
  • Integrate segment slopes before removing a reference line.
  • An endpoint datum and a minimum-zone datum are different choices.
  • A CMM measures coordinates; software fits the requested feature.
  • Qualify probe size and offsets before compensation.
  • Three non-collinear points determine a plane, but do not establish its form quality.
  • Two nonparallel infinite planes have no constant positive separation.
  • Vertical intercept difference equals normal distance only for horizontal planes.

Revise offline: the whole Metrology and Inspection handbook as one PDF

45 pages · 2.0 MBFree to read online. Sign in to download the PDF.We save the handbook, version and request time in My downloads. Privacy policy

All chapters · Corrections