Linear measurement
An instrument reading becomes useful only after its datum, calibration and measurement direction are known. Resolution, repeatability and accuracy describe different properties. Contact force, temperature and alignment can dominate the nominal least count.
2.1 Measurement quality and correction
Accuracy describes closeness to a reference value. Precision describes agreement of repeated results; repeatability restricts those repetitions to the same conditions. Resolution is the smallest distinguishable change. Sensitivity is output change per input change. Calibration establishes the relation between indications and reference values; it is not necessarily an adjustment.
Systematic effects include zero offset, scale error and thermal bias. Random variation limits precision; repeating readings does not remove a fixed bias. Hysteresis is the difference in indication on approaching the same input from opposite directions. Backlash is lost motion after reversal. Parallax is a viewing-direction error on separated scale planes. Measurement uncertainty is not the same as the observed error or the product tolerance.
2.2 Vernier and screw instruments
A vernier resolves the difference between two scale intervals. A micrometer converts screw rotation into axial travel; a ratchet or friction thimble helps maintain contact force. Always count any visible half-millimetre sleeve mark before reading the thimble.
A height gauge references a surface plate; a depth gauge references its base. An internal micrometer or bore gauge must be aligned with the intended diameter. A telescopic gauge transfers a bore size to an external measuring instrument; it does not supply its own scale reading.
2.3 Slip gauges and temperature
Slip gauges are end standards: their calibrated lengths combine by wringing clean, flat faces. Use the fewest suitable blocks to reduce interfaces, handling and accumulated uncertainty. Build the smallest decimal increment first using the available set, then the larger remainder. Do not assume every nominal size exists in every set.
20 °C is the standard reference for dimensional measurement. If an expanding scale is used, the indicated value is not automatically the physical length at that temperature: account for both scale and workpiece expansion. See the NIST gauge-block handbook for the reference-temperature convention.
2.4 Cosine and Abbe errors
The measuring line should coincide with the line of the dimension. Abbe's principle reduces the first-order error caused by an angularly imperfect carriage carrying an offset scale. A cosine error remains possible even with no offset.
2.5 Screw-thread size measurement
Past papers · ME 2020–2026 (10 papers): 1 question, 2 marks
Major diameter is measured over crests, minor diameter at roots, and pitch diameter where ridge and groove widths are equal in the axial section. Pitch is axial spacing between corresponding adjacent thread points; lead is advance in one revolution. Pitch gauges identify pitch, while a toolmaker's microscope can inspect flank angles and profile.
Last-minute recall
- Correction has the opposite sign to indication error.
- Fine resolution alone does not establish accuracy.
- Screw travel per turn is lead; pitch equals lead only for one start.
- Wring a short stack of available slip gauges; do not invent a block size.
- Temperature differences in °C and K have the same numerical value.
- Cosine projection error is quadratic in small angle; Abbe error is linear.
- The three-wire angle is the half-angle of the thread.