Chapter 1

Limits, fits and gauging

Begin with the four limiting sizes, not the fit name. A dimension tolerance controls a range of sizes; a fit describes how two such ranges interact. Gauges test conformity without reporting a continuous size value.

1.1 Sizes, deviations and material limits

Basic size BB is the reference from which deviations are specified. Actual size is obtained by measurement. The upper and lower limits bound acceptable size. A unilateral tolerance zone lies on one side of the basic size; a bilateral zone extends on both sides, with equal or unequal deviations.

Maximum material condition (MMC) leaves the most solid material: the smallest hole and largest shaft. Least material condition (LMC) is the largest hole and smallest shaft. A larger hole removes more material; this reverses the shaft rule.

1.2 Fit classification and allowance

Past papers · ME 2020–2026 (10 papers): 4 questions, 4 marks

Calculate the smallest and largest possible signed hole-minus-shaft differences. This works for clearance, transition and interference fits without guessing from the symbols.

Condition on limitsFitConsequence
Cmin⁡≥0C_{\min}\ge0ClearanceNo size interference, with possible line contact at equality
Cmax⁡≤0C_{\max}\le0InterferenceNo size clearance, with possible line contact at equality
Cmin⁡<0<Cmax⁡C_{\min}<0<C_{\max}TransitionSome pairs clear; others interfere

The degenerate case Cmin⁡=Cmax⁡=0C_{\min}=C_{\max}=0 is exact line-to-line size. A transition fit need not have zero mean clearance.

Hole and shaft tolerance zones for the transition-fit example; the dashed zero line is the basic size.Hole and shaft tolerance zones for the transition-fit example; the dashed zero line is the basic size.

1.3 Basis systems and tolerance grades

Past papers · ME 2020–2026 (10 papers): 1 question, 2 marks

A letter locates a tolerance zone; the IT number gives its width. Holes use capital letters, shafts lowercase. In 40H7/g640\mathrm{H7/g6}, 40 mm is the basic size, H7 the hole class and g6 the shaft class. Do not read the grade as a deviation.

System or zoneDefining conditionHow the fit is varied
Hole basis HEI=0EI=0, hence Dmin⁡=BD_{\min}=BChange shaft zone
Shaft basis hes=0es=0, hence dmax⁡=Bd_{\max}=BChange hole zone
Symmetric JS or jsLimits straddle zero symmetricallyNominal deviations are ±T/2\pm T/2

The fundamental deviation locates the zone relative to the zero line. The H hole and h shaft have a zero fundamental deviation. Use supplied deviation tables for other letters; do not infer every fit from its letter alone. Hole basis is common because standard hole-making tools can be retained while shaft sizes are varied.

The conventional grade series runs from IT01, IT0, IT1 through IT18. Smaller grade numbers indicate tighter tolerances at the same size. The table above covers the commonly calculated grades; use given standard values for other grades or sizes. It is not correct to replace the listed multipliers by successive exact powers of 1.6.

1.4 Limit gauges and Taylor's principle

A GO gauge should verify the maximum-material boundary over the mating length and combine relevant size and form effects. A NOT GO gauge checks an individual size element at the least-material limit. Acceptance requires GO to pass and NOT GO not to pass under the specified gauging procedure, without forcing.

GO gauges experience repeated rubbing. A plug becomes smaller with wear; a ring or gap opening becomes larger. New-gauge wear provision therefore moves a GO plug toward larger diameter and a GO ring/gap toward smaller opening, subject to the chosen gauge-tolerance scheme. NOT GO gauges usually have no wear provision.

Last-minute recall

  • Hole MMC is its lower size limit; shaft MMC is its upper size limit.
  • Subtract deviations to obtain tolerance; do not add their magnitudes blindly.
  • Signed clearance always means hole minus shaft.
  • Fit tolerance is the sum of hole and shaft tolerances.
  • H fixes the hole lower deviation at zero; h fixes the shaft upper deviation at zero.
  • GO checks MMC; NOT GO checks individual size elements at LMC.
  • Use the geometric mean of the size step in the tolerance-factor formula.

Revise offline: the whole Metrology and Inspection handbook as one PDF

45 pages · 2.0 MBFree to read online. Sign in to download the PDF.We save the handbook, version and request time in My downloads. Privacy policy

All chapters · Corrections