Angular measurement
Angles may be read directly or inferred from lengths. Length-based methods are usually more accurate when the geometry is well conditioned. Keep included angles, half-angles and reflected-beam angles distinct.
3.1 Sine bars and sine centres
Past papers · ME 2020–2026 (10 papers): 1 question, 2 marks
A sine bar has equal-diameter rollers with a calibrated centre spacing. The work surface is adjusted parallel to the reference plane using a comparator; the slip-height difference then determines angle. Sine centres apply the same geometry to work held between centres.
Above about 45°, height errors and bar-length errors become increasingly amplified; 45° is a practical preference, not a mathematical cut-off. Near 90°, the sine-bar method is ill conditioned. An unknown taper mounted on a sine bar may require converting the measured half-angle to its included angle.
Equal roller radii cancel; the sine relation uses the support-height difference and centre spacing.
3.2 Tapers, rollers and V-grooves
Past papers · ME 2020–2026 (10 papers): 1 question, 2 marks
In a symmetric V-groove, two different rollers or balls give the groove angle without needing the absolute apex position. The measured height must be identified as the top, centre or bottom height; the following formula uses top heights.
3.3 Autocollimators and precision levels
An autocollimator sends collimated light to a plane reflector and measures the returned image shift. A reflector rotation doubles the beam's angular change. A precision spirit level converts tilt into motion of a bubble along a curved vial; an electronic level senses inclination electrically.
The reflection factor of two is confirmed by the manufacturer's optical-principle guide. A calibrated autocollimator scale usually already reports the mirror angle; do not divide its displayed angle by two again.
3.4 Direct angle instruments and reversal
A bevel protractor measures the angle between its stock and blade; read the main degree scale and the coincident vernier. Convert minutes and seconds before trigonometry. Angle blocks can be combined additively or subtractively by reversing their slopes. A precision square checks 90°; an optical polygon supplies multiple angular reference faces.
Last-minute recall
- Sine-bar length means roller-centre distance, not overall bar length.
- Use the difference of support heights; equal roller radii cancel.
- A V-groove top height includes one radius above the roller centre.
- Taper diameter change is twice the radial change.
- An autocollimator doubles beam deflection, not its already calibrated angle reading.
- A level measures slope; a height profile requires integration along the surface.
- Reversal cancels a fixed zero offset only with consistent signs.