Chapter 4

Unsteady conduction

Start with the Biot number. A lumped body cools almost uniformly; a body with internal gradients needs a spatial solution. Characteristic lengths in these two methods are not always the same.

4.1 Biot number and lumped cooling

Past papers · ME 2020–2026 (10 papers): 3 questions, 5 marks

A lumped model treats the solid as a thermal capacitance connected to its fluid through a convection resistance. Use constant properties, a uniform initial temperature, and constant ambient temperature and convection coefficient.

Shape and exposed boundaryLc=V/AsL_c=V/A_s
Wall of total thickness 2b2b, both large facesbb
Wall of thickness bb, one face exposed, other insulatedbb
Long cylinder of radius bb, lateral area onlyb/2b/2
Sphere of radius bbb/3b/3

4.2 Lumped systems with a heat source

For a uniform body with constant internal power, the final temperature can exceed the fluid temperature. Sum conductances when several surfaces exchange with different reservoirs.

4.3 Finite bodies with internal gradients

When lumping fails, use the solution matching geometry and boundary condition. The following series use a uniform initial temperature TiT_i, constant h,k,αh,k,\alpha, no generation and convection to constant T∞T_\infty.

GeometryEigenvalue equationSpatial factor Φj\Phi_j
Wall, −b≤x≤b-b\le x\le bλjtan⁡λj=Bib\lambda_j\tan\lambda_j=\mathrm{Bi}_bcos⁡(λjx/b)\cos(\lambda_jx/b)
Long solid cylinderλjJ1(λj)/J0(λj)=Bib\lambda_jJ_1(\lambda_j)/J_0(\lambda_j)=\mathrm{Bi}_bJ0(λjr/b)J_0(\lambda_jr/b)
Solid sphere1−λjcot⁡λj=Bib1-\lambda_j\cot\lambda_j=\mathrm{Bi}_bsin⁡(λjr/b)/(λjr/b)\sin(\lambda_jr/b)/(\lambda_jr/b)

Here x,rx,r are position coordinates (m), and J0,J1J_0,J_1 are Bessel functions of the first kind. The sphere factor is one at r=0r=0, by its limit.

The volume-average excess ratio multiplies each series term by sin⁡λj/λj\sin\lambda_j/\lambda_j for a wall, 2J1(λj)/λj2J_1(\lambda_j)/\lambda_j for a cylinder, or 3(sin⁡λj−λjcos⁡λj)/λj33(\sin\lambda_j-\lambda_j\cos\lambda_j)/\lambda_j^3 for a sphere. Use the average temperature, not the centre temperature, to compute stored energy.

4.4 Short-time penetration into a thick solid

A semi-infinite model is appropriate before the temperature disturbance reaches the far boundary. The solid initially has uniform TiT_i and occupies x≥0x\ge0.

A useful penetration scale is αt\sqrt{\alpha t}; the distant boundary must lie well beyond it. The mathematical initial flux singularity comes from imposing an instantaneous surface-temperature step.

Last-minute recall

  • Compute V/AsV/A_s using only the exposed area.
  • Biot compares internal and external resistance; Fourier is dimensionless time.
  • After one time constant, a lumped excess temperature is 1/e1/e of its initial value.
  • Use the initial-to-ambient excess in the cooling logarithm.
  • Finite-body eigenvalue formulas use half-thickness or radius.
  • A one-term estimate should not be used at arbitrarily small time.
  • Heat content depends on volume-average temperature.
  • A semi-infinite model is a short-time or sufficiently thick-body approximation.

Revise offline: the whole Heat Transfer handbook as one PDF

50 pages · 1.9 MBFree to read online. Sign in to download the PDF.We save the handbook, version and request time in My downloads. Privacy policy

All chapters · Corrections