Unsteady conduction
Start with the Biot number. A lumped body cools almost uniformly; a body with internal gradients needs a spatial solution. Characteristic lengths in these two methods are not always the same.
4.1 Biot number and lumped cooling
Past papers · ME 2020–2026 (10 papers): 3 questions, 5 marks
A lumped model treats the solid as a thermal capacitance connected to its fluid through a convection resistance. Use constant properties, a uniform initial temperature, and constant ambient temperature and convection coefficient.
| Shape and exposed boundary | |
|---|---|
| Wall of total thickness , both large faces | |
| Wall of thickness , one face exposed, other insulated | |
| Long cylinder of radius , lateral area only | |
| Sphere of radius |
4.2 Lumped systems with a heat source
For a uniform body with constant internal power, the final temperature can exceed the fluid temperature. Sum conductances when several surfaces exchange with different reservoirs.
4.3 Finite bodies with internal gradients
When lumping fails, use the solution matching geometry and boundary condition. The following series use a uniform initial temperature , constant , no generation and convection to constant .
| Geometry | Eigenvalue equation | Spatial factor |
|---|---|---|
| Wall, | ||
| Long solid cylinder | ||
| Solid sphere |
Here are position coordinates (m), and are Bessel functions of the first kind. The sphere factor is one at , by its limit.
The volume-average excess ratio multiplies each series term by for a wall, for a cylinder, or for a sphere. Use the average temperature, not the centre temperature, to compute stored energy.
4.4 Short-time penetration into a thick solid
A semi-infinite model is appropriate before the temperature disturbance reaches the far boundary. The solid initially has uniform and occupies .
A useful penetration scale is ; the distant boundary must lie well beyond it. The mathematical initial flux singularity comes from imposing an instantaneous surface-temperature step.
Last-minute recall
- Compute using only the exposed area.
- Biot compares internal and external resistance; Fourier is dimensionless time.
- After one time constant, a lumped excess temperature is of its initial value.
- Use the initial-to-ambient excess in the cooling logarithm.
- Finite-body eigenvalue formulas use half-thickness or radius.
- A one-term estimate should not be used at arbitrarily small time.
- Heat content depends on volume-average temperature.
- A semi-infinite model is a short-time or sufficiently thick-body approximation.