Chapter 3

Fins and extended surfaces

A fin conducts energy away from its base while losing it along its sides. Match the tip boundary condition before using a standard result. Distinguish the heat carried by one fin from the total heat loss of a finned base.

3.1 Fin model

Use a one-dimensional model when temperature variation across each fin section is small. Assume steady conditions, uniform material and cross-section, constant lateral convection coefficient, no internal generation, and negligible radiation.

An axial conduction path feeds distributed convection along a fin.An axial conduction path feeds distributed convection along a fin.

3.2 Long and insulated-tip fins

Past papers · ME 2020–2026 (10 papers): 2 questions, 3 marks

A long-fin model means that the tip temperature excess is negligible. An insulated tip has zero axial temperature gradient at its end.

For an adiabatic-tip fin, mL≥2.65mL\ge2.65 makes its heat rate at least 99% of the infinite-fin rate. This is a heat-rate criterion, not a claim that the tip has exactly reached ambient temperature.

3.3 Other tip conditions

Use the convective-tip solution when tip loss is significant. A corrected length gives a convenient approximation for a slender uniform fin with the same convection coefficient on its tip and sides.

3.4 Efficiency, effectiveness and fin arrays

Efficiency compares a fin with an ideal fin held everywhere at the base temperature. Effectiveness compares it with the bare base footprint that it replaces. These conventional measures assume heat enters only at the base and leaves by convection; a prescribed-temperature tip connected to another heat reservoir needs a separate energy balance.

Last-minute recall

  • AcA_c carries conduction; AfA_f exchanges heat with the fluid.
  • Temperature excess, not absolute temperature, decays along a fin.
  • Insulated-tip heat rate is the infinite-fin rate times tanh⁡(mL)\tanh(mL).
  • Include the tip area only for the boundary model that uses it.
  • Corrected length approximates a convective tip; it is not a new physical length.
  • Fin effectiveness can exceed one; ordinary fin efficiency cannot.
  • Subtract fin footprints before computing bare-base convection.

Revise offline: the whole Heat Transfer handbook as one PDF

50 pages · 1.9 MBFree to read online. Sign in to download the PDF.We save the handbook, version and request time in My downloads. Privacy policy

All chapters · Corrections