A convection correlation is a model tied to a geometry, flow regime and thermal boundary condition. Calculate dimensionless groups first, select the correlation second, and recover the dimensional coefficient last. Use properties at the temperature specified by the correlation.
5.1 Boundary layers and dimensionless groups
Past papers · ME 2020–2026 (10 papers): 4 questions, 5 marks
At a no-slip wall, heat crosses the adjacent fluid by molecular conduction. Fluid motion outside that layer determines the wall gradient. The thermal boundary layer is the region in which the temperature differs appreciably from the free stream.
Group
Physical interpretation
Re
Inertia relative to viscous effects
Pr
Momentum diffusivity divided by thermal diffusivity
Nu
Convection relative to conduction across the same fluid length scale
Pe
Advection relative to thermal diffusion
With y∗=y/L and θ∗=(T−T∞)/(Ts−T∞), Nu=−[∂θ∗/∂y∗]s: it is a dimensionless wall-temperature gradient. Both starred variables are dimensionless.
Prandtl-number comparison
Relative thickness
Pr>1
Thermal diffusion is slower; δt<δ
Pr≃1
Thicknesses are comparable
Pr<1
Thermal diffusion reaches farther; δt>δ
5.2 Flow over a flat plate
Past papers · ME 2020–2026 (10 papers): 1 question, 1 mark
For the standard isothermal plate, evaluate fluid properties at film temperature Tf=(Ts+T∞)/2. The plate is aligned with a uniform free stream; pressure gradient, compressibility and viscous heating are negligible.
For the laminar isothermal plate, hˉL=2hx=L; for turbulence from the leading edge, hˉL=1.25hx=L. If both faces see the same independent flow, double the one-face heat rate.
5.3 Flow through pipes: development and energy balance
Past papers · ME 2020–2026 (10 papers): 3 questions, 5 marks
Internal flow has a bulk-mean temperature Tm, defined by the energy carried across the section. A thermally developed profile has a fixed dimensionless shape; its dimensional temperature may still change downstream.
For constant cp, Tm=∫AcρuTdA/m˙, with m˙=∫AcρudA. Here u is local axial velocity (m/s), Ac flow area (m²), ρ density (kg/m³), and m˙ mass flow (kg/s). Thermal development means
∂x∂[Ts(x)−Tm(x)Ts(x)−T(r,x)]=0,
where r is the transverse radial coordinate and x the downstream coordinate (m), Ts the wall temperature, and T the local fluid temperature. For the following developed-flow results, take constant properties and negligible viscous heating. Thermal development does not mean ∂T/∂x=0. At uniform wall heat flux, dTs/dx=dTm/dx; at uniform wall temperature, dTm/dx decays exponentially for constant h.
A smooth circular pipe is conventionally laminar below ReD≃2300, transitional between roughly 2300 and 4000, and turbulent above that. Many turbulent heat-transfer correlations require ReD≥104. Development in turbulent flow is much shorter in diameters than in many laminar cases; follow the length restriction of the chosen correlation.
With constant properties and negligible viscous heating, for a constant wall temperature the heat rate is also hˉAsΔTlm, formed from the two wall-to-bulk endpoint differences. With constant heat flux and fully developed constant-property flow, h is constant and Ts−Tm=q′′/h is constant, while both temperatures rise linearly.
5.4 Pipe heat-transfer coefficients
Past papers · ME 2020–2026 (10 papers): 2 questions, 3 marks
Evaluate ordinary internal-flow properties at mean bulk temperature (Tm,i+Tm,o)/2, except the wall viscosity in a viscosity-corrected relation.
5.5 Buoyancy, turbulence and analogies
Past papers · ME 2020–2026 (10 papers): 3 questions, 3 marks
Free convection comes from buoyancy in a gravitational field. For a fluid with positive thermal expansion coefficient, fluid next to a hot vertical wall rises; fluid next to a cold wall sinks. Turbulence strengthens mixing outside the thin wall region and usually increases both heat transfer and pressure loss.
In the Boussinesq approximation, density is treated as constant except in buoyancy. With an upward positive coordinate, the buoyancy acceleration is gβ(T−T∞) (m/s²). It is a force per unit mass, not a force ratio. Require small fractional density change, ∣β(T−T∞)∣≪1. The Grashof number compares buoyancy with viscous effects using the viscous velocity scale ν/L; the Richardson number compares buoyancy with imposed-flow inertia.
For a circular pipe, Cf=fF=fD/4, so the corresponding analogy uses fD/8, not fD/2. fF denotes the Fanning friction factor. A hydraulic friction factor and an external-plate skin-friction coefficient must not be substituted without checking definitions.
Last-minute recall
Choose fluid properties and characteristic length before computing dimensionless groups.
Plate correlations distinguish local and mean coefficients.
Transition at 5×105 is a conventional estimate, not a universal boundary.
Pipe wall temperature and bulk temperature can both vary in fully developed flow.
Constant wall temperature and constant heat flux give different laminar constants.
Fluid heating uses exponent 0.4 in Dittus–Boelter.
Free-convection Rayleigh number is GrPr.
Use absolute temperature in β=1/Tf.
Darcy friction factor is four times Fanning friction factor.
Revise offline: the whole Heat Transfer handbook as one PDF
50 pages · 1.9 MBFree to read online. Sign in to download the PDF.We save the handbook, version and request time in My downloads. Privacy policy