Chapter 5

Three-phase induction machines

The stator creates a rotating field; relative motion induces rotor emf and current. Rotor current produces torque through its interaction with the air-gap field. Slip connects speed, rotor frequency, rotor loss and developed power.

5.1 Rotating field, construction and harmonics

Past papers · EE 2020–2026 (7 papers): 2 questions, 2 marks

Three balanced sinusoidal phase currents in identical windings 120 electrical degrees apart create a constant-amplitude fundamental rotating MMF. Interchanging any two supply lines reverses it. Cage rotors have shorted bars and end rings; wound rotors permit external resistance through slip rings.

FeatureFunction
Skewed rotor slotsReduce tooth locking/cogging and selected space-harmonic torque; add some leakage
Deep rotor barsSkin effect raises effective rotor resistance at high rotor frequency; resistance falls during normal low-slip running
Double cageOuter cage: higher resistance, lower leakage reactance; inner cage: lower resistance, higher leakage reactance
Wound rotorExternal resistance improves starting torque and permits dissipative speed control

At start, high rotor frequency favours the low-reactance outer cage. At low slip, reactance drops and the low-resistance inner cage carries more current. Space harmonics of order 6k+16k+1 rotate forward at ns/(6k+1)n_s/(6k+1) and 6k−16k-1 backward at ns/(6k−1)n_s/(6k-1) for balanced fundamental currents and a symmetric winding. The forward seventh harmonic can cause crawling near ns/7n_s/7. These are space harmonic speeds; time harmonics at a fixed pole count have a different frequency scaling.

5.2 Slip, rotor frequency and operating modes

Past papers · EE 2020–2026 (7 papers): 3 questions, 3 marks

Take the stator field direction as positive; nn is signed rotor speed. Rotor-current frequency is nonnegative even when slip is negative.

SlipSpeed relative to fieldOperation
s<0s<0n>nsn>n_sInduction generation; external drive supplies mechanical power
0<s<10<s<10<n<ns0<n<n_sMotoring
s=1s=1Rotor stationaryStarting/blocked rotor
s>1s>1Rotor moves opposite the new fieldPlugging/braking; electrical and mechanical inputs become heat
s=0s=0Rotor at field speedIdeal induced rotor emf and torque are zero

The fundamental rotor MMF travels at snssn_s relative to the rotor, so its signed speed relative to the stator is n+sns=nsn+sn_s=n_s. After reversing phase sequence from a normal motoring state, new slip is 2−sold2-s_{\rm old} relative to the reversed field. Induction generation needs magnetising reactive power from a grid or suitably excited capacitor system; negative slip does not itself provide excitation.

5.3 Per-phase equivalent circuit

R1,X1R_1,X_1 are stator resistance/leakage reactance; R2′,X2′R'_2,X'_2 are stator-referred rotor resistance and standstill leakage reactance (Ω). Rc∥jXmR_c\parallel jX_m is the excitation branch across the air-gap voltage. Reactances refer to supply frequency. V‾1\underline V_1 is stator phase voltage.

One-phase induction equivalent circuit referred to the stator, with the conversion resistance separated from rotor copper resistance.One-phase induction equivalent circuit referred to the stator, with the conversion resistance separated from rotor copper resistance.

A physical rotor resistance is referred using the square of the effective phase turns ratio (including winding factors). If the stator-to-rotor effective ratio is nrn_r, then R2′=nr2R2R'_2=n_r^2R_2 and I2=nrI2′I_2=n_r I'_2; verify winding connections before converting line currents.

5.4 Power flow and efficiency

Past papers · EE 2020–2026 (7 papers): 2 questions, 2 marks

PinP_{\rm in} is three-phase electrical input, PagP_{\rm ag} air-gap power, PconvP_{\rm conv} developed mechanical power, and PoutP_{\rm out} shaft output (all W). I1I_1 and I2′I'_2 are phase current magnitudes. The main displayed flow is normal motoring.

If only rotor copper loss is retained, motor efficiency is 1−s1-s. Internal mechanical conversion efficiency Pconv/Pag=1−sP_{\rm conv}/P_{\rm ag}=1-s is not the complete motor efficiency when other losses exist.

5.5 Torque–speed curve and maximum torque

Past papers · EE 2020–2026 (7 papers): 2 questions, 4 marks

Define XΣ=XTh+X2′X_\Sigma=X_{\rm Th}+X'_2 and D=RTh2+XΣ2D=\sqrt{R_{\rm Th}^2+X_\Sigma^2}, both Ω. Use the same frequency and Thevenin model for every compared operating point.

Torque–speed curves from the Thevenin equation: increasing rotor resistance shifts the peak towards lower speed without changing its motoring height.Torque–speed curves from the Thevenin equation: increasing rotor resistance shifts the peak towards lower speed without changing its motoring height.

For a constant load torque below breakdown, the normal small-slip intersection is stable; the high-slip intersection is unstable in the usual curve. Always compare torque slopes if the load itself depends on speed.

5.6 No-load and blocked-rotor tests

In the no-load test apply rated frequency/voltage and measure total input P0P_0, phase voltage V0,phV_{0,\rm ph} and phase current I0I_0. A blocked-rotor test uses reduced voltage at its stated frequency to limit current. Convert line readings using the actual star/delta connection.

To separate rotational loss, plot no-load input minus stator copper loss against squared voltage at fixed frequency over a range where speed stays nearly constant. Extrapolation gives the approximate rotational-loss intercept. An exact circuit fit retains stator voltage drop, stator leakage vars and the rotor current required to supply mechanical loss; the simple extraction uses terminal voltage as air-gap voltage.

If the blocked-rotor test uses frequency ftf_t, scale the extracted leakage reactance to fNf_N by XN≃XtfN/ftX_N\simeq X_t f_N/f_t. Rotor skin effect can change resistance; the simple scaling is a constant-parameter approximation. Equal leakage division X1=X2′=Xbr/2X_1=X'_2=X_{\rm br}/2 is an assumption, not something measured by the test.

5.7 Starting methods

Past papers · EE 2020–2026 (7 papers): 1 question, 2 marks

Let IDOL,τDOLI_{\rm DOL},\tau_{\rm DOL} be starting supply current and torque with rated voltage applied directly in the intended running connection. kvk_v is motor-voltage/rated-voltage ratio. All comparisons assume the same locked-rotor impedance and supply frequency.

Rotor-resistance starting is available only with an accessible wound rotor. Increasing resistance can raise starting torque up to the maximum-torque condition; further increase reduces torque. Cage motors use their built-in rotor design, a reduced-voltage starter or a variable-frequency drive.

5.8 Speed control and constant flux

Past papers · EE 2020–2026 (7 papers): 3 questions, 6 marks

Changing frequency changes synchronous speed; changing rotor resistance changes slip at the same synchronous speed. Below base frequency, constant V/fV/f approximately preserves air-gap flux if stator voltage drop is small. A low-frequency voltage boost compensates that drop.

With stator impedance neglected, the full torque expression under constant V/fV/f depends on slip frequency alone (for constant rotor parameters), so constant slip frequency also preserves torque beyond the small-slip approximation on the same branch. Above base speed, voltage is capped: flux weakens, and ideal breakdown torque scales as 1/f21/f^2. Rated-current power capability is approximately constant over a limited region, not all speeds.

Last-minute recall

  • Field speed is 120f/p120f/p; mechanical rad/s is 4πf/p4\pi f/p.
  • Rotor frequency is ∣s∣f|s|f; slip itself can be negative.
  • The equivalent circuit uses standstill rotor reactance and resistance divided by slip.
  • Rotor copper loss is sPagsP_{\rm ag}, not sPinsP_{\rm in}.
  • Torque is air-gap power divided by synchronous mechanical speed.
  • Added rotor resistance shifts breakdown slip but not breakdown torque in the constant-parameter model.
  • Autotransformer supply current falls as the square of the tap ratio.
  • Star–delta starting gives one-third DOL line current and torque.
  • Constant V/fV/f and torque preserve slip frequency under the stated approximations.
  • Double cages combine high effective starting resistance with low running resistance.

Revise offline: the whole Electrical Machines handbook as one PDF

49 pages · 2.2 MBFree to read online. Sign in to download the PDF.We save the handbook, version and request time in My downloads. Privacy policy

All chapters · Corrections