Chapter 6

Single-phase induction motors

A single sinusoidal stator winding produces a pulsating field. It can be resolved into two oppositely rotating fields, which explains the absence of starting torque and the role of an auxiliary winding. Running characteristics depend on both fields.

6.1 Double-revolving-field principle

Past papers · EE 2020–2026 (7 papers): 1 question, 1 mark

Let BmB_m be the peak pulsating space-fundamental flux density (T), θe\theta_e electrical space angle, and ω=2πf\omega=2\pi f. Choose forward rotation as positive and let s=(ns−n)/nss=(n_s-n)/n_s.

6.2 Auxiliary winding and starting types

Past papers · EE 2020–2026 (7 papers): 1 question, 1 mark

An auxiliary winding displaced in space from the main winding carries a phase-shifted current. The two fields then give nonzero starting torque. Reversing one winding relative to the other reverses the intended starting direction; reversing both does not.

TypeStarting arrangementRunning behaviour
Resistance split-phaseHigh-resistance auxiliary winding creates moderate phase separation; disconnected after accelerationMain winding supplies running field
Capacitor startLarge starting capacitor in series with auxiliary winding; disconnected after startingHigh starting torque; capacitor alone does not improve running power factor once disconnected
Permanent capacitor / capacitor runSmaller capacitor remains connected with auxiliary windingSmoother torque and improved running power factor; moderate starting torque
Capacitor start, capacitor runLarge effective capacitance at start, smaller run capacitance retainedStrong start and typically best running power factor among the listed conventional types
Shaded poleShorted shading turn delays flux in part of the poleWeak starting torque; motion is from unshaded towards shaded portion

The ranking is a typical design comparison, not a universal numerical power-factor value. Starting switches disconnect the designated starting circuit only; a run capacitor is intended for continuous operation.

Last-minute recall

  • A pulsating field is two opposite rotating fields of half amplitude.
  • At standstill their torques cancel.
  • Forward slip is ss; backward slip is 2−s2-s.
  • Rotor frequency must be calculated separately for each field.
  • An auxiliary winding needs both spatial and time-phase displacement.
  • A start capacitor removed from circuit cannot correct running power factor.
  • A retained run capacitor improves steady-state operation.

Revise offline: the whole Electrical Machines handbook as one PDF

49 pages · 2.2 MBFree to read online. Sign in to download the PDF.We save the handbook, version and request time in My downloads. Privacy policy

All chapters · Corrections