Chapter 4

DC machines

The commutator makes the external armature current unidirectional while individual armature coils alternate their connection. The same electromagnetic structure can motor or generate. Determine armature current from the field connection before using emf or torque equations.

4.1 Emf, torque and winding paths

pp is pole count, ZaZ_a the total number of active armature conductors, AaA_a the number of parallel paths, Φ\Phi the flux per pole (Wb), nn speed (rpm), and IaI_a armature current (A). The subscript on ZaZ_a distinguishes conductor count from impedance.

Use developed power EaIaE_aI_a for electromagnetic torque. Shaft torque differs because of rotational losses. For constant field, the SI torque constant Km=KΦK_m=K\Phi and back-emf constant Kb=KΦK_b=K\Phi are numerically equal when speed is in rad/s; an rpm-based emf constant has a different numerical value.

4.2 Motoring and generating circuits

Past papers · EE 2020–2026 (7 papers): 1 question, 2 marks

VV is terminal voltage, RaR_a armature resistance, RfR_f shunt-field resistance, RseR_{se} series-field resistance, and VbV_b total brush-contact drop across the brush pair. Use positive current magnitudes along the actual power-flow direction in the following table.

4.3 Characteristics and self-excitation

The open-circuit characteristic (OCC) plots generated emf against field current at fixed speed. Residual flux gives a small initial emf; saturation bends the curve. The internal characteristic includes armature reaction; the external characteristic also includes armature and brush voltage drops.

MachineMain characteristicLimitation or observation
Separately excited generatorAt fixed field/speed, terminal voltage falls with load through series drop and armature reactionField supply is independent of terminal voltage
Shunt generatorTerminal-voltage fall also reduces field current and fluxVoltage can collapse beyond its useful load range
Series generatorVoltage initially grows with current, then saturates; large series drop can make it fallLittle voltage without load except residual emf
Shunt/separately excited motorNearly constant flux; torque nearly proportional to IaI_aSpeed falls with armature drop unless flux weakens appreciably
Unsaturated series motorΦ∝Ia\Phi\propto I_a, so τe∝Ia2\tau_e\propto I_a^2High starting torque; dangerous light-load speed
Saturated series motorFlux changes little, so torque becomes approximately proportional to IaI_aDo not apply the square-current rule in saturation

Reversing only field connections or only rotation changes the build-up condition. Loss of residual magnetism may require field flashing with the correct polarity. A DC series motor must not be run unloaded: the small flux permits excessive speed to develop the necessary back emf.

4.4 Armature reaction and commutation

Armature MMF distorts the main field. With brushes on the geometrical neutral axis its idealised effect is cross-magnetising; saturation can still reduce average pole flux. Brush shift introduces a demagnetising component. The magnetic neutral axis moves with rotation for a generator and against rotation for a motor.

During commutation a brush shorts a coil while its current reverses. Coil inductance resists reversal; incomplete reversal causes sparking. Interpoles, connected in series with the armature, provide commutating emf in the neutral zone. Compensating windings under pole faces oppose armature reaction and are also series-connected with the armature. Neither is a substitute for the other over the whole pole face.

4.5 Speed control and braking

Past papers · EE 2020–2026 (7 papers): 4 questions, 7 marks

Use the load torque to find the new armature current before using the speed ratio. Φ1,Φ2\Phi_1,\Phi_2 are the actual fluxes, including any specified armature-reaction reduction.

ControlEffectCost or limit
Armature voltage, fixed fieldSpeed below base roughly follows voltage; rated current gives constant-torque capabilityBack emf and winding current limits
Field weakening at rated armature voltageSpeed above base; torque capability falls as flux decreasesApproximate constant-power region; mechanical/commutation limits
Armature series resistanceLowers speed at loadExternal Ia2RI_a^2R loss; weak speed regulation
Series-motor field diverterReduces field current relative to armature current and weakens fluxUse the actual current split and magnetisation law

4.6 DC losses and the no-load test

Past papers · EE 2020–2026 (7 papers): 1 question, 2 marks

For a shunt motor at constant voltage and approximately constant speed, a no-load test separates field copper and armature copper losses from rotational loss. Iline,0I_{\rm line,0} is no-load line current, Ia0=Iline,0−IfI_{a0}=I_{\rm line,0}-I_f armature current, and ProtP_{\rm rot} combines core, friction and windage losses.

Last-minute recall

  • Simplex lap has pp parallel paths; simplex wave has two.
  • Motor back emf is below supply by armature and brush drops.
  • Generator armature current includes the shunt-field current.
  • Use developed torque for EaIa/ωmE_aI_a/\omega_m, then deduct rotational loss for shaft output.
  • Shunt-generator build-up needs reinforcing residual flux and sufficient speed.
  • Interpoles assist commutation; compensating windings oppose pole-face armature reaction.
  • A load law determines new current during speed-control calculations.
  • Field weakening raises speed and lowers torque capability.
  • Subtract field current from no-load line current before computing armature loss.