DC machines
The commutator makes the external armature current unidirectional while individual armature coils alternate their connection. The same electromagnetic structure can motor or generate. Determine armature current from the field connection before using emf or torque equations.
4.1 Emf, torque and winding paths
is pole count, the total number of active armature conductors, the number of parallel paths, the flux per pole (Wb), speed (rpm), and armature current (A). The subscript on distinguishes conductor count from impedance.
Use developed power for electromagnetic torque. Shaft torque differs because of rotational losses. For constant field, the SI torque constant and back-emf constant are numerically equal when speed is in rad/s; an rpm-based emf constant has a different numerical value.
4.2 Motoring and generating circuits
Past papers · EE 2020–2026 (7 papers): 1 question, 2 marks
is terminal voltage, armature resistance, shunt-field resistance, series-field resistance, and total brush-contact drop across the brush pair. Use positive current magnitudes along the actual power-flow direction in the following table.
4.3 Characteristics and self-excitation
The open-circuit characteristic (OCC) plots generated emf against field current at fixed speed. Residual flux gives a small initial emf; saturation bends the curve. The internal characteristic includes armature reaction; the external characteristic also includes armature and brush voltage drops.
| Machine | Main characteristic | Limitation or observation |
|---|---|---|
| Separately excited generator | At fixed field/speed, terminal voltage falls with load through series drop and armature reaction | Field supply is independent of terminal voltage |
| Shunt generator | Terminal-voltage fall also reduces field current and flux | Voltage can collapse beyond its useful load range |
| Series generator | Voltage initially grows with current, then saturates; large series drop can make it fall | Little voltage without load except residual emf |
| Shunt/separately excited motor | Nearly constant flux; torque nearly proportional to | Speed falls with armature drop unless flux weakens appreciably |
| Unsaturated series motor | , so | High starting torque; dangerous light-load speed |
| Saturated series motor | Flux changes little, so torque becomes approximately proportional to | Do not apply the square-current rule in saturation |
Reversing only field connections or only rotation changes the build-up condition. Loss of residual magnetism may require field flashing with the correct polarity. A DC series motor must not be run unloaded: the small flux permits excessive speed to develop the necessary back emf.
4.4 Armature reaction and commutation
Armature MMF distorts the main field. With brushes on the geometrical neutral axis its idealised effect is cross-magnetising; saturation can still reduce average pole flux. Brush shift introduces a demagnetising component. The magnetic neutral axis moves with rotation for a generator and against rotation for a motor.
During commutation a brush shorts a coil while its current reverses. Coil inductance resists reversal; incomplete reversal causes sparking. Interpoles, connected in series with the armature, provide commutating emf in the neutral zone. Compensating windings under pole faces oppose armature reaction and are also series-connected with the armature. Neither is a substitute for the other over the whole pole face.
4.5 Speed control and braking
Past papers · EE 2020–2026 (7 papers): 4 questions, 7 marks
Use the load torque to find the new armature current before using the speed ratio. are the actual fluxes, including any specified armature-reaction reduction.
| Control | Effect | Cost or limit |
|---|---|---|
| Armature voltage, fixed field | Speed below base roughly follows voltage; rated current gives constant-torque capability | Back emf and winding current limits |
| Field weakening at rated armature voltage | Speed above base; torque capability falls as flux decreases | Approximate constant-power region; mechanical/commutation limits |
| Armature series resistance | Lowers speed at load | External loss; weak speed regulation |
| Series-motor field diverter | Reduces field current relative to armature current and weakens flux | Use the actual current split and magnetisation law |
4.6 DC losses and the no-load test
Past papers · EE 2020–2026 (7 papers): 1 question, 2 marks
For a shunt motor at constant voltage and approximately constant speed, a no-load test separates field copper and armature copper losses from rotational loss. is no-load line current, armature current, and combines core, friction and windage losses.
Last-minute recall
- Simplex lap has parallel paths; simplex wave has two.
- Motor back emf is below supply by armature and brush drops.
- Generator armature current includes the shunt-field current.
- Use developed torque for , then deduct rotational loss for shaft output.
- Shunt-generator build-up needs reinforcing residual flux and sufficient speed.
- Interpoles assist commutation; compensating windings oppose pole-face armature reaction.
- A load law determines new current during speed-control calculations.
- Field weakening raises speed and lowers torque capability.
- Subtract field current from no-load line current before computing armature loss.