Chapter 3

Electromechanical energy conversion

Electrical input can become copper heat, stored magnetic energy or mechanical work. Energy and coenergy are two descriptions of the same magnetic state; the derivative must hold the correct electrical variable fixed. Mechanical angle is used for torque derivatives.

3.1 Energy balance and motional emf

Past papers · EE 2020–2026 (7 papers): 1 question, 1 mark

For a winding, v,iv,i are instantaneous voltage/current, RR is resistance, and ψe\psi_e is flux linkage (Wb-turn, conventionally Wb). Positive electrical power enters the converter; positive electromagnetic torque τe\tau_e drives positive mechanical angle θm\theta_m.

For a moving coil, find linked flux as a function of position, then differentiate with the chosen terminal polarity. Equivalently, sum conductor motional emfs using the velocity–field cross product and connection directions; spatially opposing contributions may cancel. Faraday and Lorentz laws themselves are covered in the Electromagnetic Fields and Waves handbook.

3.2 Energy and coenergy derivatives

A single-valued, reversible flux-linkage relation ψe(i,θm)\psi_e(i,\theta_m) permits energy methods. Saturation is allowed; hysteresis is not included in this state-function model.

3.3 Linear singly and doubly excited systems

L(θm)L(\theta_m) is self-inductance and M(θm)M(\theta_m) is signed mutual inductance (H), with signs fixed by the coil dots. For two coils, L1,L2L_1,L_2 are self-inductances and i1,i2i_1,i_2 instantaneous currents (A).

3.4 Acceleration, load work and stability

Past papers · EE 2020–2026 (7 papers): 2 questions, 3 marks

JJ is total shaft-referred inertia (kg·m²), τL\tau_L is resisting load torque, and τloss\tau_{\rm loss} represents mechanical/core loss torque when modelled at the shaft. Do not include the same loss in two terms.

Under a specified torque–speed envelope, minimum acceleration time uses the largest permissible electromagnetic torque at each speed, provided there are no additional thermal, current-slew or trajectory constraints.

Last-minute recall

  • Terminal electrical power includes copper heat before conversion.
  • Flux linkage, not flux alone, appears in i dψei\,d\psi_e.
  • Differentiate energy at fixed linkage and coenergy at fixed current.
  • Mechanical-angle derivatives give mechanical torque.
  • Linear reluctance torque drives towards larger inductance.
  • Mutual-inductance torque depends on both winding currents and their signs.
  • Acceleration consumes kinetic energy as well as load work.
  • The stable operating point has a restoring net torque slope.