Measuring voltage and current
Choose the instrument by what it responds to: mean current, mean square, or a product of signals. Its input impedance is part of the circuit. Ideal-meter assumptions must be stated before using them.
2.1 Deflection principles
A pointer settles when mean deflecting torque equals controlling torque. Spring control gives ; damping suppresses oscillation and ideally gives no torque at rest. Gravity control depends on orientation and gives .
| Instrument | Ideal response | Use and qualification |
|---|---|---|
| PMMC, without rectifier | Signed mean current | DC; symmetrical AC gives zero mean torque |
| Moving iron | Mean square current | AC/DC; generally nonuniform scale; practical frequency and hysteresis errors |
| Electrodynamic, coils in series | Mean square current | AC/DC transfer instrument; air core avoids iron hysteresis |
| Electrostatic voltmeter | Mean square voltage | AC/DC voltage; very high DC input resistance, capacitive AC loading |
| Thermal/thermocouple | Heating proportional to mean square | True RMS within thermal and frequency limits; slow response |
2.2 Ammeter shunts and voltmeter multipliers
Let a DC movement have full-scale current (A) and coil resistance (Ω). The shunt goes in parallel; a multiplier goes in series.
2.3 Loading and resistance by voltmeter–ammeter
An ideal voltmeter has infinite input resistance; an ideal ammeter has zero series resistance. Real meters disturb the value they measure.
2.4 Rectifier and true-RMS instruments
An average-responding rectifier meter can carry an RMS-labelled scale. That calibration is exact only for its calibration waveform. Ideal diodes and sufficient movement averaging are assumed below.
| Symmetrical waveform with peak magnitude | ||||
|---|---|---|---|---|
| Sine | ||||
| Square, equal positive/negative durations | ||||
| Triangle |
2.5 Ohmmeters and insulation measurements
A resistance measurement supplies its own test current. Disconnect external power. Four-wire sensing separates current-lead voltage drops from the voltage measured across the unknown.
Last-minute recall
- PMMC without rectification responds to signed mean current.
- Ideal mean-square response does not imply unlimited frequency performance.
- Shunt in parallel; multiplier in series.
- Ohms per volt equals reciprocal full-scale current.
- Include meter loading before interpreting an indication.
- A sine-calibrated rectifier scale can be wrong for nonsinusoidal inputs.
- Distinguish AC-only RMS from AC-plus-DC RMS.
- Four-wire sensing rejects current-lead drops.