DC bridges and potentiometers
A bridge compares ratios; a potentiometer compares a voltage with a known opposing voltage. At null, the detector draws no current, so its resistance does not enter the ideal balance equation. It still affects off-null sensitivity.
3.1 Wheatstone balance and arm convention
Past papers · EE 2020–2026 (7 papers): 2 questions, 3 marks
Use nodes (supply positive), (supply negative), (left detector) and (right detector). Arms are –, –, –, –. Detector polarity is .
Bridge arm labels and detector polarity. The same topology is used for four-arm AC bridges.
3.2 Bridge sensitivity and detector current
Past papers · EE 2020–2026 (7 papers): 1 question, 2 marks
Sensitivity is signed. Changing the detector terminals changes its sign. The following derivatives hold with fixed and all other arms fixed.
3.3 Kelvin double bridge
The unknown and standard carry the same main-path current, apart from the auxiliary branch. The connection resistance must be separated from the potential measurement.
Kelvin double bridge: the main path is A–B–C–D, with detector between E and F.
3.4 DC potentiometer standardisation
A uniform slide wire carries a constant working current. A standard cell establishes the voltage gradient; it is not used as the working-current source. Connect the measured emf to oppose the selected wire drop.
3.5 Potentiometer applications and AC comparison
A standard resistor converts current into a small voltage suitable for null measurement. A calibrated potential divider extends the voltage range. AC comparison must match phase as well as magnitude.
3.6 Bridge method selection
Select the method by the dominant unwanted resistance or reactance. Numerical resistance-range boundaries vary between instruments; they are not physical discontinuities.
| Measurement | Suitable method | Main precaution |
|---|---|---|
| Low resistance | Kelvin double bridge, four-terminal comparison | Contact and current-lead drops |
| Moderate resistance | Wheatstone bridge | Ratio-arm tolerance and detector sensitivity |
| High/insulation resistance | Guarded leakage measurement, loss of charge | Surface leakage, humidity, dielectric absorption |
| Inductance and coil loss | Maxwell, Hay, Owen, Anderson | Define arm connections and loss model |
| Capacitance and dielectric loss | Schering | Separate series loss from capacitance |
| Frequency | Wien bridge | Both real and imaginary balance conditions |
Last-minute recall
- At bridge null the detector resistance drops out of the ratio.
- Source resistance changes available signal, not the ideal balance ratio.
- Sensitivity needs a specified input arm and output polarity.
- Match both Kelvin ratios to cancel link resistance.
- Standardise the potentiometer working current before comparison.
- A null potentiometer measures emf without drawing source current.
- AC null requires equal phase and equal magnitude.