Chapter 1

Errors, uncertainty and sensitivity

Decide whether the question gives a signed error, a maximum tolerance or a standard uncertainty. They require different calculations. Keep the reference value and the instrument range separate.

1.1 Error and calibration conventions

Accuracy describes agreement with a reference; precision describes repeatability. Resolution is the smallest distinguishable increment. High resolution alone guarantees neither accuracy nor precision. Calibration estimates the relation between indication and reference; adjustment changes the instrument.

Error sourceTypical causeUseful remedy
GrossWrong terminal, range or transcriptionRepeat and inspect the setup
SystematicZero offset, gain drift, loadingCalibrate or correct the measurement model
RandomNoise and uncontrolled fluctuationsRepeated independent observations
ObservationalParallax or interpolationMirror scale, normal viewing direction

1.2 Sensitivity and limiting-error propagation

Past papers · EE 2020–2026 (7 papers): 2 questions, 3 marks

For output y=F(x1,…,xn)y=F(x_1,\ldots,x_n), sensitivity to xix_i is the local slope ci=∂F/∂xic_i=\partial F/\partial x_i, with units [y]/[xi][y]/[x_i]. A large slope magnifies both a wanted input change and uncertainty in that input.

1.3 Random uncertainty and repeated readings

A maximum bound is not a standard deviation. Root-sum-square applies to independent standard uncertainties, not automatically to component tolerances.

1.4 Nonlinear measurement models

Past papers · EE 2020–2026 (7 papers): 1 question, 2 marks

Differentiate before inserting numbers. Retain offsets and subtractive terms if they are comparable with the signal. Device physics belongs to the Electronic Devices handbook; here the device equation is only a supplied measurement model.

1.5 Decibel reporting

Past papers · EE 2020–2026 (7 papers): 1 question, 1 mark

Power attenuation is often reported as a positive loss. Keep it distinct from a signed gain.

Last-minute recall

  • Error is indication minus reference; correction reverses its sign.
  • A full-scale error becomes a larger percentage at a small reading.
  • Maximum errors add through absolute sensitivities.
  • Independent standard uncertainties combine through squares.
  • Shared variables require differentiation before error combination.
  • Repetition reduces random scatter, not a common bias.
  • Keep the minus one in an exponential model unless neglect is justified.
  • Use ten times the logarithm for a power ratio.

Revise offline: the whole Electrical and Electronic Measurements handbook as one PDF

48 pages · 2.0 MBFree to read online. Sign in to download the PDF.We save the handbook, version and request time in My downloads. Privacy policy

All chapters · Corrections