Network equations and reductions
KCL and KVL are sufficient for lumped circuit analysis when combined with element laws. Choose the representation that needs fewer unknowns; do not assume a bridge is a series-parallel network.
2.1 KCL, KVL and division
Past papers · EC 2020–2026 (7 papers): 1 question, 1 mark
By KCL, the signed currents leaving any node total zero; by KVL, the oriented voltage drops around any closed path total zero. For a connected graph with nodes and branches, there are independent node equations and independent loop equations.
A bridge with arms (top left), (bottom left), (top right), (bottom right) has no current in the midpoint bridge when , provided it is driven between top and bottom and the midpoint connection contains no independent excitation. This follows by equating the two divider voltages.
2.2 Node and supernode analysis
Past papers · EC 2020–2026 (7 papers): 7 questions, 7 marks · EE 2020–2026 (7 papers): 2 questions, 2 marks
Choose a reference node at 0 V. Let be node 's voltage and the independent current injected into it. Current from node to through admittance is .
For a voltage source between two nonreference nodes, make a supernode: sum KCL over both nodes, omit the internal source current and add its voltage constraint . Alternatively retain the source current as an extra unknown. A source to ground directly specifies its node voltage. A controlled voltage source gives the same constraint using its control relation.
For parallel branches each consisting of source (positive toward the common node) in series with , KCL gives , where is an additional current injected into that node. This is a direct one-node equation.
2.3 Mesh and supermesh analysis
Mesh currents belong to the smallest faces of a planar circuit. Choose all mesh currents clockwise. On a shared branch, the physical current is the algebraic difference of adjacent mesh currents.
A current source on the outer boundary fixes a mesh current, with sign. A current source shared by two meshes requires a supermesh KVL around their union and a current constraint, such as for an arrow along mesh 1's traversal. Do not guess the unknown voltage of a current source.
2.4 Wye–delta transformation
Use this transformation for three-terminal networks without internal sources. Wye arms connect terminals to a floating centre. Delta sides are .
Last-minute recall
- In a divider, check that the elements actually share one current or voltage.
- Complex impedances obey the same KCL and KVL as resistors.
- Ground removes one redundant node equation.
- A supernode needs its voltage constraint.
- A supermesh needs its current constraint.
- Mesh analysis requires a planar circuit; nodal analysis does not.
- A delta side is the wye product-sum divided by the opposite arm.