Elements, references and stored energy
Fix voltage polarities and current arrows before reducing a circuit. A negative answer then changes the physical direction, not the equations. Ideal elements impose exact constraints, which may make a proposed interconnection inconsistent.
1.1 Reference directions and ideal sources
Past papers · EE 2020–2026 (7 papers): 6 questions, 6 marks
The passive sign convention (PSC) takes current entering the terminal labelled positive for voltage . A branch is a two-terminal connection between nodes; an essential node or junction joins at least three branches. All points joined by ideal wire are one node.
| Ideal element | Constraint | Remaining variable |
|---|---|---|
| Voltage source | Prescribed terminal voltage | Current determined by network |
| Current source | Prescribed branch current | Voltage determined by network |
| Open circuit / ideal voltmeter | Voltage need not be zero | |
| Short circuit / ideal ammeter | Current need not be zero |
Equal ideal voltage sources may be parallel; unequal prescribed voltages may not. Series ideal current sources must prescribe the same oriented current. An ideal voltage source shorted at nonzero voltage, or a nonzero current source opened, has no finite solution.
1.2 Resistance, inductance and capacitance
Assume constant positive resistance (Ω), inductance (H) and capacitance (F). Charge is in coulombs and flux linkage in Wb. A resistor dissipates energy; ideal inductors and capacitors store it.
At a settled DC operating point, is a short and an open. This statement requires an actual steady state: an ideal capacitor driven by a constant nonzero current ramps indefinitely.
1.3 Dependent sources
Past papers · EE 2020–2026 (7 papers): 1 question, 1 mark
A controlled source remains active when independent sources are suppressed. Read the marked direction of both its controlling variable and its output before writing an equation.
Last-minute recall
- Mark PSC before multiplying voltage and current.
- An ideal voltage source fixes voltage, not current.
- An ideal current source fixes current, not voltage.
- Count nodes by conducting connections, not drawing corners.
- At settled DC: capacitor open, inductor short.
- Use the uncoupled-inductor reductions only when .
- Controlled sources stay in test-source circuits.