Linear-network theorems
These theorems reduce work; they do not remove the need for terminal directions. Keep the source network fixed when varying a load, and distinguish linear source models from supplies with current or voltage limits.
3.1 Superposition and source transformation
In a linear circuit, the voltage or current response is the sum of responses to independent sources acting separately. Set a suppressed ideal voltage source to zero volts (short) and a suppressed ideal current source to zero amperes (open). Retain dependent sources and internal resistances. Initial stored energy is another excitation in transient superposition.
3.2 Thevenin and Norton equivalents
Past papers · EC 2020–2026 (7 papers): 2 questions, 3 marks · EE 2020–2026 (7 papers): 5 questions, 7 marks
Define terminal voltage and load current leaving the source network at . A linear one-port has an affine terminal relation. For AC, use complex quantities at one frequency.
A network with only dependent sources generally has in its unique unexcited state: the ratio tells nothing about impedance. Use a test source. From two terminal measurements with load current outward, ; with current inward, the slope is positive.
3.3 Maximum power transfer
Past papers · EC 2020–2026 (7 papers): 2 questions, 3 marks · EE 2020–2026 (7 papers): 2 questions, 4 marks
Use RMS Thevenin voltage and write , . Assume , and a source network unaffected by the choice of load.
At a conjugate match, load resistance and Thevenin resistance dissipate equal power: the equivalent series circuit has 50% efficiency. This is not necessarily the overall efficiency of an internally active source network. If constraints prevent the optimum, compare allowed boundary values. For negative or zero , the usual finite-maximum theorem is inapplicable.
A current-limited supply is piecewise, not one linear Thevenin model across its whole range. If it maintains current up to voltage and then constant voltage, maximum load power occurs at and equals .
3.4 Reciprocity
Reciprocity concerns interchange of excitation and response ports in a linear reciprocal network, with matched orientations and all other independent sources suppressed. Passive bilateral RLC networks with reciprocal mutual coupling satisfy it; arbitrary controlled-source networks need not.
Last-minute recall
- Keep dependent sources during source suppression.
- Norton short-circuit current points through the external short toward the return.
- Test current enters the one-port; load current leaves it.
- For two measurements, check the current arrow before taking the slope.
- Complex matching cancels reactance and matches resistance.
- Resistive-only matching uses the magnitude of source impedance.
- Reciprocity and port symmetry are separate properties (EC).