Chapter 2

Block diagrams and signal-flow graphsECEE

Block manipulation and signal-flow graphs describe the same linear equations. Choose the representation with fewer opportunities to lose a sign or a take-off connection.

2.1 Series, parallel and feedback reductionECEE

Past papers · EC 2020–2026 (7 papers): 3 questions, 4 marks · EE 2020–2026 (7 papers): 2 questions, 2 marks

Blocks in cascade multiply only when the interconnection does not change the individual block models. Parallel paths add algebraically, including their signs.

For nested loops, reduce the innermost isolated loop first. If a take-off point or summing junction crosses the proposed boundary, write the node equations instead. For several independent inputs, find one transfer path at a time by setting the other independent inputs to zero.

2.2 Moving junctions without changing signalsECEE

Keep the signal at every outgoing branch identical before and after a move. This gives the conversion factor directly and is safer than memorising arrow pictures.

Conditions: these are algebraic transformations. An inverse block may be noncausal or unstable; its appearance in a reduction does not imply that it can be built. Never move a junction and keep all its branch gains unchanged unless G=1G=1.

2.3 Mason's gain formulaECEE

Past papers · EC 2020–2026 (7 papers): 1 question, 2 marks · EE 2020–2026 (7 papers): 1 question, 1 mark

A node holds a signal; each directed branch carries a gain. Incoming branch contributions add at the node. A forward path visits no node twice. A loop returns to its starting node without repeating another node. Loops are non-touching only if they share no node.

Two non-touching self-loops contribute a product term to the determinant.Two non-touching self-loops contribute a product term to the determinant.

Last-minute recall

  • Parallel path signs are part of the gains.
  • A take-off point duplicates a signal; it does not divide it.
  • Keep branch signals unchanged when moving junctions.
  • A negative branch can make a loop gain negative before Mason's outer minus sign.
  • Non-touching means no common node, including a forward-path endpoint.
  • If all loops touch a forward path, its cofactor is 11.

Revise offline: the whole Control Systems handbook as one PDF

53 pages · 1.9 MBFree to read online. Sign in to download the PDF.We save the handbook, version and request time in My downloads. Privacy policy

All chapters · Corrections