Transient response of LTI systems
Poles set the natural time scales; zeros and residues determine how much of each mode is visible. Standard second-order expressions are exact only for the stated numerator and denominator.
3.1 Inputs, residues and endpoint values
Past papers · EC 2020–2026 (7 papers): 1 question, 1 mark
Zero-state output is the input convolved with the impulse response. Standard test inputs probe different low-frequency behaviours. Use one-sided Laplace transforms for causal signals.
| Causal input for | Laplace transform | Amplitude convention |
|---|---|---|
| Impulse | is impulse area, input-unit·s | |
| Step | is input amplitude | |
| Ramp | is slope, input-unit/s | |
| Parabola | is input acceleration, input-unit/s | |
| Sine | in rad/s |
3.2 First-order response
Past papers · EE 2020–2026 (7 papers): 3 questions, 4 marks
A stable single pole gives a monotone step response. Normalise the output by its final change before applying percentage definitions.
For an initially resting first-order model with final output , a measured step-response point gives . Use a point strictly between the initial and final values.
For 2% and 5% bands the exact settling times are and ; and are rounded estimates. These statements assume zero initial state, one real stable pole and no finite zero.
3.3 Standard second-order response
Past papers · EE 2020–2026 (7 papers): 2 questions, 4 marks
The natural frequency and damping ratio are obtained by normalising the coefficient of to one. A non-unit DC gain scales the response but does not change the normalised time specifications.
| Damping | Poles / unit-DC normalised step response |
|---|---|
| ; ; no settling | |
| Complex LHP pair; decaying oscillation | |
| Repeated pole ; | |
| Real LHP poles ; monotone response for this numerator | |
| , | Unstable poles; stable-response specifications do not apply |
Step-response shapes for a common natural frequency and different damping ratios.
3.4 Overshoot, rise time and settling time
Past papers · EC 2020–2026 (7 papers): 1 question, 2 marks
Specify the rise-time definition. For an underdamped second-order system, 0–100% rise time is the first crossing of the final value; it is different from 10–90% rise time.
3.5 Dominant modes and the effect of zeros
Past papers · EE 2020–2026 (7 papers): 1 question, 1 mark
An LHP pole closer to the imaginary axis decays more slowly. It dominates only if its residue is appreciable. A pole separated by roughly a factor of five in decay rate is often treated as fast, but separation alone is not a proof of a good approximation.
A nearby LHP zero can increase overshoot; an RHP zero can give an initial response opposite to the final change. Preserve DC gain when replacing a fast factor by its low-frequency value. A cancelled RHP pole can hide an unstable internal state.
Last-minute recall
- Read order, type and number of zeros separately.
- Find the actual response poles before applying the final-value theorem.
- First-order 10–90% rise time is .
- Overshoot formulas require a standard second-order numerator.
- Convert overshoot percentage to a fraction before taking a logarithm.
- Use radians in time formulas involving inverse trigonometric functions.
- Slow modes need non-negligible residues to dominate the output.