Components, models and feedback
A model must identify the input, measured output and feedback sign before any algebra starts. This chapter connects physical components to transfer functions and separates tracking, disturbance and noise paths.
1.1 Components and signal conventions
The reference specifies the desired output. A comparator produces error , a controller creates the actuation signal , the plant produces , and a sensor measures it. An actuator converts the controller signal into force, torque or another physical input. Open-loop operation does not correct the input using the measured output; closed-loop operation does.
1.2 Transfer functions and elementary models
Past papers · EE 2020–2026 (7 papers): 1 question, 1 mark
A transfer function relates an output to an input after all initial conditions are set to zero. Its denominator describes the externally visible modes after cancellation; the physical model may contain additional hidden modes.
Poles are denominator roots and zeros are numerator roots of the reduced rational function. The order is the denominator degree; a proper model has , and a strictly proper model has . A constant direct path gives a nonzero high-frequency limit. Pole-zero cancellation does not establish internal stability.
1.3 Closed-loop paths
Past papers · EE 2020–2026 (7 papers): 1 question, 1 mark
Let be the controller, the plant, the sensor, the forward path and the loop transfer. Sensor output is subtracted at the comparator. Products around a loop are dimensionless.
Negative feedback with separate plant-input disturbance and sensor-noise paths.
1.4 DC servomotor and gears
Use a constant-field armature-controlled motor model. Positive armature current produces positive shaft torque; the back emf opposes the applied armature voltage. A load torque is positive when it resists the chosen positive rotation.
If the electrical time constant is negligible over the frequencies of interest, set : the speed model becomes first order, with DC gain and time constant . The position model still has an integrator.
Conditions: rigid, lossless gears. One external mesh reverses rotation direction; signs follow the selected shaft coordinates. Two texts can give reciprocal gear ratios: always start from the speed relation, then square that ratio for inertia.
1.5 Sensitivity and feedback trade-offs
Sensitivity measures a fractional response to a fractional parameter change at a fixed frequency. It is not the absolute derivative of a gain. The following identities are algebraic; useful attenuation also requires a stable closed loop.
Large makes small and . Sensor accuracy then matters strongly. Near , becomes small and sensitivity becomes large; check the loop phase as well as its magnitude. High loop gain suppresses an output disturbance through but passes sensor noise to the output through .
1.6 Electrical analogues of mechanical systems
Match the differential equations, including their signs. The analogies below use linear mass, spring and viscous-damper elements; positive applied force or torque drives positive motion.
Last-minute recall
- Mark every summing-junction sign before reducing a loop.
- Transfer functions exclude the initial-condition response.
- The loop transfer is dimensionless even when individual blocks are not.
- Distinguish the controller, plant and sensor before writing their product.
- Positive feedback changes the characteristic denominator to .
- Feedback can improve low-frequency accuracy and still destabilise the system.