Chapter 2

Working-stress section analysis

Transform steel into an equivalent concrete area to enforce strain compatibility. First decide whether the concrete tension zone is present or cracked. The effective code modular ratio used in WSM is distinct from the instantaneous elastic ratio.

2.1 Modular ratio and an uncracked section

Past papers · CE 2020–2026 (14 papers): 2 questions, 3 marks

Concrete gradeM15M20M25M30M35M40
σcbc\sigma_{cbc}, MPa578.51011.513
Direct compression permissible stress σcc\sigma_{cc}, MPa4568910

These are WSM values from IS 456 Table 21. For ordinary flexural tension, Table 22 gives 140 MPa for Fe250 bars up to 20 mm diameter, 130 MPa for larger Fe250 bars, and 230 MPa for Fe415 and 0.55fy=2750.55f_y=275 MPa for Fe500 deformed bars. Use the specific permissible stress given in a question for other bar types or loading conditions.

2.2 Cracked rectangular section and balanced WSM design

Past papers · CE 2020–2026 (14 papers): 1 question, 2 marks

Let bb be width, dd effective depth, xx elastic neutral-axis depth from the compression face, and AstA_{st} tension steel area. Neglect tensile concrete and steel's own second moment about its centroid.

WSM under-reinforced sections reach the steel permissible stress first; over-reinforced sections reach concrete permissible stress first. This elastic classification is not the ultimate strain classification of Chapter 3.

2.3 Compression steel in elastic analysis

Compression steel reduces concrete compression for a given tensile force. In code WSM, its long-term transformed multiplier is 1.5m1.5m; this is an effective design rule, not the instantaneous modulus ratio.

For a flanged cracked section, find its transformed centroid using only concrete above xx plus transformed steel. Split the compressed concrete into non-overlapping rectangles; enforce zero first moment about the neutral axis and use the parallel-axis theorem. Do not retain a tension flange as uncracked concrete.

Last-minute recall

  • me=Es/Ecm_e=E_s/E_c; code m=280/(3σcbc)m=280/(3\sigma_{cbc}).
  • Gross uncracked section: add (m−1)As(m-1)A_s.
  • Cracked concrete tension contributes neither area nor inertia.
  • WSM rectangular compression is triangular; its resultant acts at x/3x/3.
  • Both steel and concrete allowable stresses must pass.
  • Effective compression-steel multiplier in WSM is 1.5m1.5m.

Revise offline: the whole Concrete Structures handbook as one PDF

51 pages · 2.1 MBFree to read online. Sign in to download the PDF.We save the handbook, version and request time in My downloads. Privacy policy

All chapters · Corrections