Chapter 3

Limit-state flexure of beams

At collapse, use strain compatibility, force equilibrium and the prescribed material curves. Measure all depths from the actual compression face. Under hogging, a slab flange can be in tension and contribute no concrete compression.

3.1 Strain limits and the concrete stress block

Past papers · CE 2020–2026 (14 papers): 6 questions, 9 marks

GradeFe250Fe415Fe500
Code-rounded xu,max⁡/dx_{u,\max}/d0.530.480.46
Mu,lim⁡/(fckbd2)M_{u,\lim}/(f_{ck}bd^2) using those ratios0.1480.1380.134

The exact strain equation gives approximately 0.5310.531, 0.4790.479 and 0.4560.456. Use the supplied ratio where stated; otherwise keep a consistent rounded code convention. An under-reinforced section has xu<xu,max⁡x_u<x_{u,\max} and adequate tensile strain. An over-reinforced section violates that limit and is compression-controlled; redesign it. The traditional phrase “balanced section” in GATE often denotes the code limiting section; εst,min⁡\varepsilon_{st,\min} is larger than the simple elastic yield strain.

The same depth coordinate links strain compatibility, concrete compression and steel tension.The same depth coordinate links strain compatibility, concrete compression and steel tension.

3.2 Singly reinforced rectangular beams

Past papers · CE 2020–2026 (14 papers): 1 question, 2 marks

3.3 Doubly reinforced beams

Past papers · CE 2020–2026 (14 papers): 2 questions, 3 marks

Use compression steel when the permitted depth cannot supply the required singly reinforced resistance. Compression-steel stress comes from its strain and steel curve; it is not automatically 0.87fy0.87f_y.

For Fe250 with a definite yield plateau, fsc=min⁡(Esεsc,fy/1.15)f_{sc}=\min(E_s\varepsilon_{sc},f_y/1.15). For cold-worked Fe415/Fe500, use the design stress–strain curve or supplied table. The standard design-curve points below permit linear interpolation; below the first point use fsc=Esεscf_{sc}=E_s\varepsilon_{sc}. Stresses use fy/1.15f_y/1.15 rather than the rounded 0.87fy0.87f_y.

Stress fraction of fy/1.15f_y/1.15Fe415 strainFe415 stress (MPa)Fe500 strainFe500 stress (MPa)
0.8000.00144288.70.00174347.8
0.8500.00163306.70.00195369.6
0.9000.00192324.80.00226391.3
0.9500.00241342.80.00277413.0
0.9750.00276351.80.00312423.9
1.0000.00380360.90.00417434.8

At design proof stress the strain is about 0.00380 for Fe415 and 0.00417 for Fe500. Since flexural compression strain is below 0.0035, cold-worked Fe500 compression steel cannot reach that proof-stress plateau in this model. Fe250 can. Raising AscA_{sc} or lowering AstA_{st} moves a previously limiting section towards under-reinforced behaviour.

3.4 Flanged beams

Let bwb_w denote web width, bfb_f effective flange width and DfD_f flange thickness. A compression flange must act compositely with the web. An isolated flange cannot recruit adjacent slab width that does not exist.

3.5 Continuous-beam coefficients and redistribution

The coefficient method is for substantially uniform loading on uniform sections over at least three spans; span differences must not exceed 15% of the longest. It already accounts for adverse variable-load placement.

LoadEnd-span positive cMc_MInterior-span positive cMc_MFirst interior support cMc_MOther interior support cMc_M
Dead and fixed imposed1/121/121/161/16−1/10-1/10−1/12-1/12
Variable imposed1/101/101/121/12−1/9-1/9−1/9-1/9
LoadEnd support cVc_VFirst interior, outer sideFirst interior, inner sideOther interior supports
Dead and fixed imposed0.400.600.550.50
Variable imposed0.450.600.600.60

At unequal adjacent spans, average the two calculated negative support moments. Do not redistribute moments obtained from this coefficient method. A member partially restrained in a masonry wall may require a support moment −wl2/24-wl^2/24; the corresponding end shear coefficient increases by 0.05.

Last-minute recall

  • Flexural concrete extreme strain is 0.0035.
  • The rectangular-width resultant is 0.36fckbxu0.36f_{ck}bx_u at 0.42xu0.42x_u.
  • Prove xu≤xu,max⁡x_u\le x_{u,\max} before using yielded-steel formulas.
  • A flange in tension contributes no concrete compression.
  • Compression-steel stress follows its strain; Fe500 need not reach 0.87fy0.87f_y.
  • Subtract displaced concrete when the compression block includes steel positions.
  • An equal-area substitute stress block may have a different lever arm.
  • Redistribution requires equilibrium and extra rotational capacity.

Revise offline: the whole Concrete Structures handbook as one PDF

51 pages · 2.1 MBFree to read online. Sign in to download the PDF.We save the handbook, version and request time in My downloads. Privacy policy

All chapters · Corrections