Limit-state flexure of beams
At collapse, use strain compatibility, force equilibrium and the prescribed material curves. Measure all depths from the actual compression face. Under hogging, a slab flange can be in tension and contribute no concrete compression.
3.1 Strain limits and the concrete stress block
Past papers · CE 2020–2026 (14 papers): 6 questions, 9 marks
| Grade | Fe250 | Fe415 | Fe500 |
|---|---|---|---|
| Code-rounded | 0.53 | 0.48 | 0.46 |
| using those ratios | 0.148 | 0.138 | 0.134 |
The exact strain equation gives approximately , and . Use the supplied ratio where stated; otherwise keep a consistent rounded code convention. An under-reinforced section has and adequate tensile strain. An over-reinforced section violates that limit and is compression-controlled; redesign it. The traditional phrase “balanced section” in GATE often denotes the code limiting section; is larger than the simple elastic yield strain.
The same depth coordinate links strain compatibility, concrete compression and steel tension.
3.2 Singly reinforced rectangular beams
Past papers · CE 2020–2026 (14 papers): 1 question, 2 marks
3.3 Doubly reinforced beams
Past papers · CE 2020–2026 (14 papers): 2 questions, 3 marks
Use compression steel when the permitted depth cannot supply the required singly reinforced resistance. Compression-steel stress comes from its strain and steel curve; it is not automatically .
For Fe250 with a definite yield plateau, . For cold-worked Fe415/Fe500, use the design stress–strain curve or supplied table. The standard design-curve points below permit linear interpolation; below the first point use . Stresses use rather than the rounded .
| Stress fraction of | Fe415 strain | Fe415 stress (MPa) | Fe500 strain | Fe500 stress (MPa) |
|---|---|---|---|---|
| 0.800 | 0.00144 | 288.7 | 0.00174 | 347.8 |
| 0.850 | 0.00163 | 306.7 | 0.00195 | 369.6 |
| 0.900 | 0.00192 | 324.8 | 0.00226 | 391.3 |
| 0.950 | 0.00241 | 342.8 | 0.00277 | 413.0 |
| 0.975 | 0.00276 | 351.8 | 0.00312 | 423.9 |
| 1.000 | 0.00380 | 360.9 | 0.00417 | 434.8 |
At design proof stress the strain is about 0.00380 for Fe415 and 0.00417 for Fe500. Since flexural compression strain is below 0.0035, cold-worked Fe500 compression steel cannot reach that proof-stress plateau in this model. Fe250 can. Raising or lowering moves a previously limiting section towards under-reinforced behaviour.
3.4 Flanged beams
Let denote web width, effective flange width and flange thickness. A compression flange must act compositely with the web. An isolated flange cannot recruit adjacent slab width that does not exist.
3.5 Continuous-beam coefficients and redistribution
The coefficient method is for substantially uniform loading on uniform sections over at least three spans; span differences must not exceed 15% of the longest. It already accounts for adverse variable-load placement.
| Load | End-span positive | Interior-span positive | First interior support | Other interior support |
|---|---|---|---|---|
| Dead and fixed imposed | ||||
| Variable imposed |
| Load | End support | First interior, outer side | First interior, inner side | Other interior supports |
|---|---|---|---|---|
| Dead and fixed imposed | 0.40 | 0.60 | 0.55 | 0.50 |
| Variable imposed | 0.45 | 0.60 | 0.60 | 0.60 |
At unequal adjacent spans, average the two calculated negative support moments. Do not redistribute moments obtained from this coefficient method. A member partially restrained in a masonry wall may require a support moment ; the corresponding end shear coefficient increases by 0.05.
Last-minute recall
- Flexural concrete extreme strain is 0.0035.
- The rectangular-width resultant is at .
- Prove before using yielded-steel formulas.
- A flange in tension contributes no concrete compression.
- Compression-steel stress follows its strain; Fe500 need not reach .
- Subtract displaced concrete when the compression block includes steel positions.
- An equal-area substitute stress block may have a different lever arm.
- Redistribution requires equilibrium and extra rotational capacity.