Shear, torsion and serviceability
Flexural strength is only one check. Shear can fail abruptly, torsion needs a closed reinforcement path, and service-load deflection or cracking may control dimensions even when collapse resistance is adequate.
4.1 Beam shear and stirrup design
Past papers · CE 2020–2026 (14 papers): 3 questions, 5 marks
IS 456 Table 19 values below are MPa. Interpolate between listed reinforcement percentages; do not extrapolate above the final row.
| (%) | M20 | M25 | M30 | M35 | M40 and above |
|---|---|---|---|---|---|
| 0.28 | 0.29 | 0.29 | 0.29 | 0.30 | |
| 0.25 | 0.36 | 0.36 | 0.37 | 0.37 | 0.38 |
| 0.50 | 0.48 | 0.49 | 0.50 | 0.50 | 0.51 |
| 0.75 | 0.56 | 0.57 | 0.59 | 0.59 | 0.60 |
| 1.00 | 0.62 | 0.64 | 0.66 | 0.67 | 0.68 |
| 1.25 | 0.67 | 0.70 | 0.71 | 0.73 | 0.74 |
| 1.50 | 0.72 | 0.74 | 0.76 | 0.78 | 0.79 |
| 1.75 | 0.75 | 0.78 | 0.80 | 0.82 | 0.84 |
| 2.00 | 0.79 | 0.82 | 0.84 | 0.86 | 0.88 |
| 2.25 | 0.81 | 0.85 | 0.88 | 0.90 | 0.92 |
| 2.50 | 0.82 | 0.88 | 0.91 | 0.93 | 0.95 |
| 2.75 | 0.82 | 0.90 | 0.94 | 0.96 | 0.98 |
| 0.82 | 0.92 | 0.96 | 0.99 | 1.01 |
| Grade | M15 | M20 | M25 | M30 | M35 | M40 and above |
|---|---|---|---|---|---|---|
| Beam (MPa) | 2.5 | 2.8 | 3.1 | 3.5 | 3.7 | 4.0 |
If , increase dimensions or concrete grade; extra stirrups cannot cure diagonal compression failure. If , ordinary beams still require minimum stirrups. The code permits omission in qualifying minor members where calculated shear is below half the permissible value; do not assume every beam qualifies.
Vertical stirrup spacing must not exceed ; at , the limit is . Select the smallest spacing imposed by strength, minimum reinforcement and maximum-spacing rules.
Near a compressive support, the code permits concrete shear enhancement for , where is the distance of the considered section from the support face; tension steel must be adequately anchored, and face shear must remain below . For generally uniform loading, or a principal load beyond , the section at from the support face can govern the near-support design when the reaction compresses the end region. This exception does not apply automatically to a hanging support.
4.2 Combined torsion, bending and shear
Past papers · CE 2020–2026 (14 papers): 1 question, 1 mark
The following IS 456 rules apply to solid rectangular sections. Using web width for a flanged beam is a conservative code extension. Equilibrium torsion must be resisted; compatibility torsion may be released only when the indeterminate structure can redistribute it safely.
4.3 Deflection, cracking and effective span
For a simply supported member not built integrally into its supports, effective span is the smaller of clear span plus and centre-to-centre support distance. For a cantilever it is length to the support face plus , except at the end of a continuous beam, where use the support centre. For continuous members with supports narrower than , use the simply supported rule. For wide supports (wider than the smaller of and 600 mm), intermediate spans and fixed–continuous end spans use clear span. A discontinuous–continuous end span uses clear span plus the smaller of and half the discontinuous-support width. Roller/rocker bearing spans use bearing-centre distance; continuous-frame analysis uses support-centre distance.
Use the given chart/factor when a problem supplies one. For a direct calculation use the actual cracked stiffness and the load history; the uncracked gross inertia generally overestimates stiffness after cracking. General elastic deflection methods are in Structural Analysis.
General surface crack-width guidance is 0.3 mm when cracking does not impair durability; 0.2 mm where weather, moisture, soil or groundwater makes tensile cracking harmful; and 0.1 mm for particularly aggressive exposure such as very severe or extreme environments (Amendment 4). Smaller, well-distributed bars control cracks better than a few large bars carrying the same steel area. These are serviceability limits, not ultimate concrete tensile strengths.
For lateral stability, the clear distance between restraints of a simply supported or continuous beam should not exceed ; for a cantilever use . Here is the compression-face width midway between restraints.
Last-minute recall
- Shear uses , not flange width times depth.
- in the shear table is a percentage, not a decimal fraction.
- prevents diagonal compression failure.
- Two-legged stirrup area includes two legs; shear steel strength is capped at 415 MPa.
- Torsion needs closed hoops and longitudinal corner steel.
- Equivalent torsional moment uses overall depth .
- Deflection is a service-load check, with time effects included.
- Final deflection and deflection after finishes have different limits.