Chapter 5

Bond, anchorage and basic detailing

Steel can develop its calculated stress only when force transfers to the surrounding concrete. An anchorage check is local to the critical section; a long beam alone does not guarantee adequate development length at its end.

5.1 Bond transfer and development length

Past papers · CE 2020–2026 (14 papers): 1 question, 1 mark

ConcreteM20M25M30M35M40 and above
LSM τbd\tau_{bd}, plain bars in tension (MPa)1.21.41.51.71.9
WSM τbd\tau_{bd}, plain bars in tension (MPa)0.80.91.01.11.2

Multiply by 1.60 for deformed bars and by a further 1.25 for compression. Fusion-bonded epoxy-coated bars use 80% of the corresponding deformed-bar bond stress. For bundles of two, three or four bars in contact, increase each individual bar's LdL_d by 10%, 20% or 33%, respectively. Do not replace these increments with an equivalent-diameter guess.

5.2 Hooks, laps and curtailed reinforcement

Increase tension lap length by 1.4 for a top-cast bar with cover less than 2ϕ2\phi, or under the corner/adjacent-lap condition: cover to either corner face below 2ϕ2\phi, or clear spacing between adjacent laps below max⁡(75 mm,6ϕ)\max(75\text{ mm},6\phi) (IS 456 26.2.5.1). When both conditions apply, use 2.0. Laps are ordinarily avoided for bars larger than 36 mm; use appropriate mechanical or welded joints. Lap centres separated by at least 1.3Llap1.3L_{\mathrm{lap}} count as staggered. Normally splice no more than half the bars at a section, away from regions exceeding half the moment resistance; otherwise provide the code's special confinement/lap precautions. A tension member's lap zone needs confinement; the code specifies at least 6 mm spirals at pitch no more than 100 mm.

Do not terminate a bar in a tension zone unless a code shear condition is met: shear at cut-off no more than two-thirds of provided shear resistance; or provide the prescribed extra stirrups; or, for bars up to 36 mm, continuing flexural steel is at least twice that required and shear is no more than three-quarters of provided resistance. The extra-stirrup option requires excess area at least 0.4bsv/fyv0.4bs_v/f_{yv} over 0.75d0.75d from cut-off and sv≤d/(8βb)s_v\le d/(8\beta_b), where βb\beta_b is the fraction of total bar area cut off.

Continue at least one-third of positive steel in simply supported members, or one-fourth in continuous members, into the support for at least Ld/3L_d/3. A primary lateral-load-resisting member needs full design-stress anchorage at the support face. At least one-third of negative support steel extends beyond inflection by max⁡(d,12ϕ,lclear/16)\max(d,12\phi,l_{\mathrm{clear}}/16).

5.3 Cover, clear spacing and beam steel limits

Nominal cover is measured to the outermost reinforcement, normally links. Effective cover is measured to the centroid of main steel. Fire resistance can require more cover than durability; adopt the controlling requirement.

ExposureMildModerateSevereVery severeExtreme
Durability nominal cover (mm)2030455075
Minimum RC grade for durabilityM20M25M30M35M40

For mild exposure with main bars up to 12 mm, cover may reduce by 5 mm. For severe/very severe exposure with M35 or higher, a 5 mm reduction is permitted. Also satisfy bar-diameter and member-specific cover requirements. Columns generally need at least 40 mm or main-bar diameter, whichever is greater; a column of minimum dimension at most 200 mm with bars at most 12 mm may use 25 mm. Footings require at least 50 mm.

Horizontal clear spacing between parallel main bars is at least the larger bar diameter or nominal maximum aggregate size plus 5 mm. Between vertical layers, clear spacing is at least the greatest of 15 mm, largest bar diameter and two-thirds aggregate size; align bars vertically where possible.

If beam web depth exceeds 750 mm, total side-face steel is at least 0.1% of web area, split equally between both faces, with spacing no more than the smaller of 300 mm and web thickness. Compression bars need lateral restraint. Place main bars so that concrete can be compacted around them.

Last-minute recall

  • Development length equates bar force to bond force over its surface.
  • Deformed-bar and compression bond multipliers act successively.
  • A tension U-hook has anchorage value 16ϕ16\phi.
  • Lap length and development length are related but not identical.
  • Curtailment requires both extension and a shear check.
  • Nominal cover reaches the link; effective cover reaches main-bar centroid.
  • Beam minimum steel uses bdbd; maximum steel uses bDbD.

Revise offline: the whole Concrete Structures handbook as one PDF

51 pages · 2.1 MBFree to read online. Sign in to download the PDF.We save the handbook, version and request time in My downloads. Privacy policy

All chapters · Corrections