Chapter 6

Slabs

Select one-way or two-way action from the support arrangement before using the span ratio. Design each direction using its own effective depth; crossed bar layers do not have the same depth.

6.1 One-way action, loads and bar spacing

Past papers · CE 2020–2026 (14 papers): 2 questions, 3 marks

A slab supported on two opposite sides acts one-way, spanning between those supports even if that distance is the longer panel dimension. With support on all four sides, ly/lx>2l_y/l_x>2 is normally treated as one-way; otherwise use two-way action. Here lx≤lyl_x\le l_y are effective spans. Main one-way reinforcement runs in the spanning direction, with distribution steel perpendicular to it.

For a simply supported strip with UDL, Mu=wul2/8M_u=w_ul^2/8 and Vu=wul/2V_u=w_ul/2 per metre width; for a cantilever use Mu=wul2/2M_u=w_ul^2/2 and Vu=wulV_u=w_ul. Here ll is the effective span in the spanning direction, wuw_u is factored load per square metre and ll is in metres, giving kN m/m and kN/m. Continuous one-way strips use analysis or the valid continuous-beam coefficient method.

6.2 Two-way load sharing and simply supported panels

Past papers · CE 2020–2026 (14 papers): 1 question, 1 mark

For simply supported four-sided panels without adequate corner torsion restraint (IS 456 Table 27):

ly/lxl_y/l_xαx\alpha_xαy\alpha_y
1.000.0620.062
1.100.0740.061
1.200.0840.059
1.300.0930.055
1.400.0990.051
1.500.1040.046
1.750.1130.037
2.000.1180.029

Interpolate between tabulated ratios. Continue at least 50% of mid-span tension steel to supports; remaining steel extends to within 0.1lx0.1l_x or 0.1ly0.1l_y of the relevant support. A panel whose corners are held down requires the restrained-panel method and corresponding detailing, not Table 27 by default.

6.3 Restrained panels, strips and corners

Past papers · CE 2020–2026 (14 papers): 1 question, 1 mark

For each direction, the middle strip occupies three-quarters of the transverse panel width; each edge strip occupies one-eighth. Table 26 moments apply to the middle strip without redistribution. Reinforcement parallel to an edge in the edge strip follows slab minimum-steel requirements plus applicable corner torsion steel.

The following compact code-coefficient tables use entries in thousandths: an entry 32 means α=0.032\alpha=0.032. A dash means no continuous-edge negative moment in that direction. A short edge has physical length lxl_x; a long edge has physical length lyl_y.

CaseDiscontinuous edges
1None (interior panel)
2One short edge
3One long edge
4Two adjacent edges
5Both short edges
6Both long edges
7Three; one long edge remains continuous
8Three; one short edge remains continuous
9All four

Short-span positive coefficients 1000αx1000\alpha_x:

Case1.01.11.21.31.41.51.752.01000αy1000\alpha_y positive
1242832363941454924
2283236394144485228
3283339444751596528
4354045495356636935
5353740434445495235
6354351576368808835
7434853576064697343
8435159657176879643
956647279858910010756

Short-span negative-moment magnitudes 1000αx1000\alpha_x at continuous edges:

Case1.01.11.21.31.41.51.752.01000αy1000\alpha_y negative
1323743475153606532
2374348515557646837
3374452576367778537
4475360657175849147
54549525659606569—
6————————45
75764717680849197—
8————————57
9—————————

In middle strips, bottom mid-span steel extends to within 0.25l0.25l of a continuous edge or 0.15l0.15l of a discontinuous edge. Top steel over continuous edges extends at least 0.15l0.15l into the panel, with at least half extending 0.30l0.30l. At a discontinuous edge, provide top steel about half the mid-span area for 0.1l0.1l into the span to allow for partial fixity. Here ll is the span of the bars being detailed.

Plan of a restrained panel: strips are defined perpendicular to the direction of the bars being designed.Plan of a restrained panel: strips are defined perpendicular to the direction of the bars being designed.

6.4 Slab minimum steel, spacing and shear

DD (mm)≤150\le150175200225250275≥300\ge300
ksk_s1.301.251.201.151.101.051.00

For two-way solid slabs use the shorter span in deflection checks. For short two-way spans up to 3.5 m and loading class up to 3 kN/m2^2, the code allows span/overall-depth ratios 35 (simply supported) and 40 (continuous) with mild steel; multiply by 0.8 for Fe415. Do not confuse these with the usual span/effective-depth ratios 20 and 26.

Last-minute recall

  • Support arrangement comes before aspect ratio.
  • One-way slabs use beam design on a unit-width strip.
  • Required bar area per metre varies as ϕ2/s\phi^2/s.
  • Both two-way code moments contain the short span squared.
  • Rankine–Grashoff load ratio is fourth power; moment ratio is second power.
  • Restrained-panel middle strip is 3/43/4 width; edge strips are 1/81/8 each.
  • Corner torsion area is specified for each of four layers.
  • Minimum slab steel uses DD; shear denominator uses dd.

Revise offline: the whole Concrete Structures handbook as one PDF

51 pages · 2.1 MBFree to read online. Sign in to download the PDF.We save the handbook, version and request time in My downloads. Privacy policy

All chapters · Corrections