Slabs
Select one-way or two-way action from the support arrangement before using the span ratio. Design each direction using its own effective depth; crossed bar layers do not have the same depth.
6.1 One-way action, loads and bar spacing
Past papers · CE 2020–2026 (14 papers): 2 questions, 3 marks
A slab supported on two opposite sides acts one-way, spanning between those supports even if that distance is the longer panel dimension. With support on all four sides, is normally treated as one-way; otherwise use two-way action. Here are effective spans. Main one-way reinforcement runs in the spanning direction, with distribution steel perpendicular to it.
For a simply supported strip with UDL, and per metre width; for a cantilever use and . Here is the effective span in the spanning direction, is factored load per square metre and is in metres, giving kN m/m and kN/m. Continuous one-way strips use analysis or the valid continuous-beam coefficient method.
6.2 Two-way load sharing and simply supported panels
Past papers · CE 2020–2026 (14 papers): 1 question, 1 mark
For simply supported four-sided panels without adequate corner torsion restraint (IS 456 Table 27):
| 1.00 | 0.062 | 0.062 |
| 1.10 | 0.074 | 0.061 |
| 1.20 | 0.084 | 0.059 |
| 1.30 | 0.093 | 0.055 |
| 1.40 | 0.099 | 0.051 |
| 1.50 | 0.104 | 0.046 |
| 1.75 | 0.113 | 0.037 |
| 2.00 | 0.118 | 0.029 |
Interpolate between tabulated ratios. Continue at least 50% of mid-span tension steel to supports; remaining steel extends to within or of the relevant support. A panel whose corners are held down requires the restrained-panel method and corresponding detailing, not Table 27 by default.
6.3 Restrained panels, strips and corners
Past papers · CE 2020–2026 (14 papers): 1 question, 1 mark
For each direction, the middle strip occupies three-quarters of the transverse panel width; each edge strip occupies one-eighth. Table 26 moments apply to the middle strip without redistribution. Reinforcement parallel to an edge in the edge strip follows slab minimum-steel requirements plus applicable corner torsion steel.
The following compact code-coefficient tables use entries in thousandths: an entry 32 means . A dash means no continuous-edge negative moment in that direction. A short edge has physical length ; a long edge has physical length .
| Case | Discontinuous edges |
|---|---|
| 1 | None (interior panel) |
| 2 | One short edge |
| 3 | One long edge |
| 4 | Two adjacent edges |
| 5 | Both short edges |
| 6 | Both long edges |
| 7 | Three; one long edge remains continuous |
| 8 | Three; one short edge remains continuous |
| 9 | All four |
Short-span positive coefficients :
| Case | 1.0 | 1.1 | 1.2 | 1.3 | 1.4 | 1.5 | 1.75 | 2.0 | positive |
|---|---|---|---|---|---|---|---|---|---|
| 1 | 24 | 28 | 32 | 36 | 39 | 41 | 45 | 49 | 24 |
| 2 | 28 | 32 | 36 | 39 | 41 | 44 | 48 | 52 | 28 |
| 3 | 28 | 33 | 39 | 44 | 47 | 51 | 59 | 65 | 28 |
| 4 | 35 | 40 | 45 | 49 | 53 | 56 | 63 | 69 | 35 |
| 5 | 35 | 37 | 40 | 43 | 44 | 45 | 49 | 52 | 35 |
| 6 | 35 | 43 | 51 | 57 | 63 | 68 | 80 | 88 | 35 |
| 7 | 43 | 48 | 53 | 57 | 60 | 64 | 69 | 73 | 43 |
| 8 | 43 | 51 | 59 | 65 | 71 | 76 | 87 | 96 | 43 |
| 9 | 56 | 64 | 72 | 79 | 85 | 89 | 100 | 107 | 56 |
Short-span negative-moment magnitudes at continuous edges:
| Case | 1.0 | 1.1 | 1.2 | 1.3 | 1.4 | 1.5 | 1.75 | 2.0 | negative |
|---|---|---|---|---|---|---|---|---|---|
| 1 | 32 | 37 | 43 | 47 | 51 | 53 | 60 | 65 | 32 |
| 2 | 37 | 43 | 48 | 51 | 55 | 57 | 64 | 68 | 37 |
| 3 | 37 | 44 | 52 | 57 | 63 | 67 | 77 | 85 | 37 |
| 4 | 47 | 53 | 60 | 65 | 71 | 75 | 84 | 91 | 47 |
| 5 | 45 | 49 | 52 | 56 | 59 | 60 | 65 | 69 | — |
| 6 | — | — | — | — | — | — | — | — | 45 |
| 7 | 57 | 64 | 71 | 76 | 80 | 84 | 91 | 97 | — |
| 8 | — | — | — | — | — | — | — | — | 57 |
| 9 | — | — | — | — | — | — | — | — | — |
In middle strips, bottom mid-span steel extends to within of a continuous edge or of a discontinuous edge. Top steel over continuous edges extends at least into the panel, with at least half extending . At a discontinuous edge, provide top steel about half the mid-span area for into the span to allow for partial fixity. Here is the span of the bars being detailed.
Plan of a restrained panel: strips are defined perpendicular to the direction of the bars being designed.
6.4 Slab minimum steel, spacing and shear
| (mm) | 175 | 200 | 225 | 250 | 275 | ||
|---|---|---|---|---|---|---|---|
| 1.30 | 1.25 | 1.20 | 1.15 | 1.10 | 1.05 | 1.00 |
For two-way solid slabs use the shorter span in deflection checks. For short two-way spans up to 3.5 m and loading class up to 3 kN/m, the code allows span/overall-depth ratios 35 (simply supported) and 40 (continuous) with mild steel; multiply by 0.8 for Fe415. Do not confuse these with the usual span/effective-depth ratios 20 and 26.
Last-minute recall
- Support arrangement comes before aspect ratio.
- One-way slabs use beam design on a unit-width strip.
- Required bar area per metre varies as .
- Both two-way code moments contain the short span squared.
- Rankine–Grashoff load ratio is fourth power; moment ratio is second power.
- Restrained-panel middle strip is width; edge strips are each.
- Corner torsion area is specified for each of four layers.
- Minimum slab steel uses ; shear denominator uses .