Columns
Classify slenderness separately about both axes, then include eccentricity. An apparently axial applied load does not eliminate the code's minimum eccentricity. A column interaction diagram is a family of capacities at different axial forces, not one fixed bending resistance.
7.1 Effective length, slenderness and eccentricity
| Ideal end restraint | IS 456 recommended |
|---|---|
| Both ends held in position and restrained against rotation | 0.65 |
| Both held in position; one restrained against rotation | 0.80 |
| Both held in position; neither restrained against rotation | 1.00 |
| One end fixed; other free in position and rotation | 2.00 |
These are design effective lengths for the stated conditions, not Euler's ideal fixed-fixed ratio 0.5. For frames, use the effective length from relative beam/column stiffness and sway restraint. A braced column has lateral stability supplied by a separate bracing system. Slenderness about the other axis can still govern.
The unsupported length must not exceed 60 times the least lateral dimension. If one end is unrestrained in a plane, an additional limit is , with dimensions as defined for that plane. A pedestal has effective length no more than three times its least lateral dimension.
7.2 Short axially loaded and helically reinforced columns
For a circular helix, compute its actual bar length per turn from helix centreline diameter : . Then , where is helix-bar area and pitch. The familiar is a small-pitch approximation that also approximates the core diameter by .
For WSM axial-column checking, use with permissible column steel stress 130 MPa for Fe250 or 190 MPa for Fe415/Fe500. Do not use beam tensile permissible stress in that expression. The LSM resistance above is the normal collapse-design formula.
7.3 Axial load with uniaxial and biaxial bending
Past papers · CE 2020–2026 (14 papers): 1 question, 2 marks
For uniaxial design choose a trial neutral axis and strain profile. Calculate concrete force from the concrete stress law and steel forces from their actual strains, subtract displaced concrete, and sum forces and moments about the section centroid. Adjust the profile to match ; the resulting moment gives the corresponding capacity. In design charts match , steel grade and reinforcement arrangement, as well as the normalised axial load and moment.
7.4 Slender columns and reinforcement details
The optional code reduction factor for additional moment is , where is balanced axial load for the section in that bending plane (highly compressed concrete strain 0.0035; extreme tension-steel strain 0.002). Use it only with the required section analysis and a valid positive factor; without that information retain the unreduced additional moment.
Every compression bar near the face needs lateral restraint from a tie corner or suitable cross-tie; a large perimeter hoop alone may leave intermediate bars unsupported. For helix strength enhancement, ; provide 1.5 extra turns at each end. is helix-bar diameter and diameter to the outside of the helix.
Last-minute recall
- Short means both effective-length/dimension ratios are below 12.
- Minimum eccentricity uses unsupported length.
- The axial formula requires the small-eccentricity condition.
- Use net concrete area in axial resistance.
- A helix earns 5% extra strength only when confinement and detailing qualify.
- Fully compressed sections approach strain 0.002 under pure compression.
- Biaxial capacities must correspond to the same axial load.
- Do not count second-order effects twice.