Centrifugal compressors
The inducer admits and turns the gas into the rotating impeller. The impeller supplies shaft work; the diffuser converts part of the exit kinetic energy into static enthalpy and pressure. Number impeller inlet 1, impeller exit 2 and diffuser exit 3.
4.1 Inducer inlet and prewhirl
Past papers · AE 2020–2026 (7 papers): 1 question, 2 marks
At the eye, use axial throughflow and the local radius. The tip usually has a larger relative speed than the hub for uniform axial velocity and zero prewhirl. This is why an inlet absolute Mach number alone is insufficient for checking inducer compressibility.
When inlet total temperature and relative Mach number are given, solve the triangle together with . Sound speed uses this static , not . With zero prewhirl, ; the metal angle relates to .
4.2 Impeller outlet, backsweep and slip
Past papers · AE 2020–2026 (7 papers): 2 questions, 3 marks
For this topic only, is the angle between the outlet relative blade direction and the negative tangent, measured towards outward radial flow. Radial blades have ; backward-curved blades have .
4.3 Diffuser recovery
Past papers · AE 2020–2026 (7 papers): 1 question, 2 marks
A vaneless diffuser allows the swirl to decay as radius grows. A vaned diffuser imposes stronger guidance and can diffuse in a shorter distance, but its incidence range is limited. Diffuser loss lowers total pressure even while static pressure rises.
Last-minute recall
- The inducer must be checked in the relative frame.
- Impeller work is .
- Radial outlet blades give ideal exit whirl equal to tip speed.
- Slip reduces exit whirl; it is not a total-pressure efficiency.
- Backsweep changes the outlet triangle and work-flow characteristic.
- The diffuser supplies no shaft work and cannot raise total pressure adiabatically.