Axial compressors
A stage has a rotor followed by a stator. The rotor supplies work and usually diffuses the relative flow; the stator removes swirl and diffuses the absolute flow. The formulas below are mean-radius, two-dimensional relations unless stated otherwise.
3.1 Stage work and pressure rise
Past papers · AE 2020–2026 (7 papers): 3 questions, 5 marks
Number the rotor inlet 1, rotor exit 2 and stator exit 3. Take blade speed and axial velocity as constant through the stage; angles retain the signed convention of Section 1.1.
For the usual positively loaded stage with constant axial speed and nonnegative inlet whirl, the rotor increases absolute speed while diffusing relative speed. The stator then reduces absolute speed. Thus total temperature rises in the rotor and stays constant in the adiabatic stator; total pressure rises in normal compressor operation but falls across a lossy stator. These speed trends depend on the triangles, whereas stator total-enthalpy conservation follows from the energy balance.
3.2 Degree of reaction
Past papers · AE 2020–2026 (7 papers): 2 questions, 3 marks
Reaction partitions the static enthalpy rise between rotor and stage. The usual compact expression assumes a repeating stage, so the inlet and outlet absolute speeds are equal (), in addition to constant .
3.3 Multistaging and annulus contraction
Past papers · AE 2020–2026 (7 papers): 3 questions, 5 marks
Stages add specific work and multiply pressure ratios. Equal work per stage does not mean equal pressure ratio, because each later stage receives hotter gas. Mass continuity determines how the annulus area changes with density.
A smaller downstream annulus can keep nearly constant as density rises. Increasing hub diameter, decreasing tip diameter, or both can provide this contraction. The overall compressor efficiency must be computed from overall inlet and outlet states; stage efficiencies are not multiplied.
3.4 Single-stage characteristics and operating limits
Past papers · AE 2020–2026 (7 papers): 3 questions, 5 marks
A compressor map plots total pressure ratio against corrected mass flow on lines of constant corrected speed, with efficiency contours. Moving towards low flow at a fixed speed generally raises positive rotor incidence and makes separation more likely. The actual curve is empirical; Euler work alone does not predict the surge boundary.
Let be the total inlet conditions for the mapped component and its fixed reference conditions.
| Limit or feature | What to recognise | Revision consequence |
|---|---|---|
| Blade-row stall | Local separation under excessive incidence or diffusion | Loss rises; a stable mean forward flow can still exist |
| Rotating stall | Nonuniform stalled cells move around the annulus | Distinct from whole-system surge |
| Surge | Compressor, ducts and storage volume develop a global oscillation | Mass-flow reversal can occur; the system matters |
| Choke | A controlling passage reaches sonic flow | Flow ceases to increase appreciably with reduced back pressure at fixed inlet total state |
| Variable guide vanes or bleed | Change incidence or flow distribution | Extend useful operation away from design |
Schematic compressor map. Curves illustrate reading the map and are not measured performance data.
Last-minute recall
- Rotor work raises ; an adiabatic stator does not.
- The pressure ratio uses stage inlet and stage efficiency.
- Work uses whirl difference; reaction uses whirl sum.
- The compact reaction expression needs a repeating stage and constant axial speed.
- Add stage work; multiply stage pressure ratios; never multiply efficiencies.
- Stall is a blade-flow event; surge involves the compressor system.