Chapter 7

Connections

Connections must deliver the member force through fasteners, plates and the receiving member. Start with a free-body diagram. Decide whether the action causes in-plane shear, bolt tension, weld-group torsion or a combination before selecting a capacity formula.

7.1 Bolt layout and hole dimensions

Pitch is measured along the load; gauge is transverse to it. End distance is measured along the load from a hole centre to the plate end; edge distance is perpendicular to the load. The nominal bolt diameter is dd and the standard clearance-hole diameter is d0d_0.

Tacking fasteners hold built-up parts together between force-transferring connections: ordinary maximum pitch is min⁡(32t,300)\min(32t,300) mm, reduced to min⁡(16t,200)\min(16t,200) mm for exposed plates. Special back-to-back tension components permit up to 1000 mm under the code's conditions; compression components have a 600 mm ceiling and must also pass the component-slenderness limit. Do not apply a tacking-bolt exception to a force-transferring end joint.

7.2 Bearing-type bolt resistance

An ordinary bearing connection transfers force by bolt shear and plate/bolt bearing after contact. A symmetric double-cover butt joint can have two shear planes; a lap joint generally has one. Check the actual shear planes rather than doubling a memorised bolt value.

For bearing normal to a slot, multiply the ordinary bearing resistance by 0.7 for oversized/short-slotted holes and by 0.5 for long-slotted holes. Net section and block shear remain separate plate checks. A concentric group of nbn_b identical equally loaded bolts has resistance nbVdbn_bV_{db} only if joint length, grip and packing reductions are accounted for.

Bolt class x.yx.y specifies nominal ultimate strength 100x100x MPa and yield strength (y/10)(100x)(y/10)(100x) MPa. Thus class 4.6 means 400/240 MPa and 8.8 means 800/640 MPa (ultimate/yield).

7.3 Long joints, large grip and packing

These modify bolt shear, not plate bearing or net rupture. Long-joint reduction does not apply to a connection whose shear transfer is uniform along its length, such as a uniformly loaded flange-to-web connection. Apply the question's explicit reduction convention if it supplies one.

7.4 Bolt tension and combined actions

7.5 Friction-grip bolts

A pretensioned HSFG bolt clamps the interfaces. Slip resistance comes from interface friction; it is not the bolt shank's shear resistance. Also check the strength limit state of the bolt and connected plates.

The long-joint factor in Section 7.3 also applies to friction-grip connections. When simultaneous tension and shear occur, use the quadratic interaction with the friction-bolt design shear and tension resistances at the chosen limit state, and include prying where present. Do not compare a service shear demand against a resistance evaluated using an unrelated ultimate-slip criterion.

7.6 Fillet and butt weld resistance

Past papers · CE 2020–2026 (14 papers): 5 questions, 8 marks

For an ordinary fillet, size sws_w is the leg size and effective throat ttt_t is the shortest root-to-face dimension. These are different dimensions. For a complete-penetration butt weld, throat equals the thinner joined part; for partial penetration, use the verified common penetration excluding reinforcement.

Thicker connected part (mm)Minimum first/single-run fillet size (mm)
Up to 103
Over 10 to 205
Over 20 to 326
Over 32 to 508 for first run; minimum weld size 10

Above 50 mm, special precautions such as preheating are needed. When the table minimum exceeds the thinner part, use the code's thinner-part/preheating provision. Also check the effective-throat minimum of 3 mm and its ordinary upper limit 0.7t0.7t (special cases permit tt), where tt is the thinner plate. At a square edge the usual maximum size is t−1.5t-1.5 mm; at a rounded rolled toe it is 0.75t0.75t.

The effective run should be at least four weld sizes. An intermittent run additionally needs at least 40 mm effective length. Clear intermittent gaps are limited to min⁡(12t,200)\min(12t,200) mm in compression and min⁡(16t,200)\min(16t,200) mm in tension. Lap overlap is at least max⁡(4t,40)\max(4t,40) mm. End returns, when practicable, extend at least 2sw2s_w around the corner. For a member attached only by two longitudinal edge welds, each weld length should be at least their transverse separation.

7.7 Eccentric bolt groups

Past papers · CE 2020–2026 (14 papers): 2 questions, 4 marks

Use an elastic group model for identical bolts in a rigid connecting plate. Let the bolt-group centroid be the origin, xx right and yy upward. Let Fx,FyF_x,F_y and counter-clockwise MgM_g be the actions to be transferred by the bolt group. The physical resisting forces on a free body have opposite signs.

Signed bolt-group force components for direct load and counter-clockwise moment.Signed bolt-group force components for direct load and counter-clockwise moment.

7.8 Eccentric weld groups and circular welds

Past papers · CE 2020–2026 (14 papers): 2 questions, 4 marks

Use the effective throat as a line distribution with area element dA=tt dldA=t_t\,dl. Take moments about its area-weighted centroid. A nonuniform throat cannot be replaced by an unweighted length centroid.

For equal-throat lines forming two vertical runs of length hh separated by bb, Jw=tt(h3/6+hb2/2)J_w=t_t(h^3/6+hb^2/2). For a closed rectangular perimeter bb by hh, add all four runs: Jw=tt[(b3+h3)/6+(bh2+hb2)/2]J_w=t_t[(b^3+h^3)/6+(bh^2+hb^2)/2]. These are line-weld inertias, not the inertia of a solid rectangle.

7.9 Prying in flexible end plates

Flexure of an end plate or angle can press its outer edge against the support and increase bolt tension. The added force is prying. A bolt calculated only from the external tension can therefore be inadequate even when the total external force is unchanged.

A negative bracket means no positive prying force in this model. The fourth power of plate thickness explains why a small thickness increase can reduce prying sharply. Check plate bending as well as bolt strength; a large bolt alone does not stiffen the end plate sufficiently.

7.10 Beam-to-column load paths

A simple connection transfers end shear while allowing the rotation assumed in analysis. Typical forms are web cleats, fin plates, flexible end plates and seated connections. Its shear line can be offset from a bolt group, so “simple” does not mean zero local connection moment. A rigid moment connection transfers the end moment and restrains relative rotation; a semi-rigid connection requires its moment–rotation behaviour in the frame model.

In a flange-couple/web-shear idealisation, flange welds or flange plates transfer FfF_f, and the web connection transfers VV. Check the column flange for local bending and the column web for local yielding/buckling and panel shear. Continuity plates help transfer concentrated flange forces; doubler plates strengthen the panel web. End-plate bolts can carry tension plus prying and shear. The intended load path must also pass through beam/column splices where present.

Do not add the nominal capacities of an ordinary bearing-bolt group and a weld group simply because both are present. Their stiffness and slip behaviour differ; use a justified shared-load detail or design a complete force path through one system. In seismic moment frames, additional ductility and capacity-design requirements apply; those specialist provisions are not implied by a generic GATE simple-connection calculation.

Last-minute recall

  • Bolt shear uses bolt strength; plate bearing uses plate strength.
  • Count shear planes and friction interfaces separately.
  • A butt splice transfers the full force through each side of the splice.
  • Bolt diameter, hole diameter, grip length and joint length are different inputs.
  • Use effective weld length once; do not subtract end allowances twice.
  • Weld size is not throat thickness.
  • Add eccentric-force components as vectors before taking a resultant.
  • Bolt-group JgJ_g has mm² units; weld-group JwJ_w has mm⁴ units.
  • Out-of-plane bracket loading creates tension as well as shear.
  • Prying adds to bolt tension.
  • A moment connection needs a complete flange-force, web-shear and panel-zone load path.

Revise offline: the whole Steel Structures handbook as one PDF

49 pages · 1.9 MBFree to read online. Sign in to download the PDF.We save the handbook, version and request time in My downloads. Privacy policy

All chapters · Corrections