Column bases
The base distributes concentrated steel forces into a larger support area. Its plate bends under the upward bearing pressure. Moment and uplift require a compatible compression contact region and anchor tension; concrete contact cannot carry tension.
6.1 Bearing pressure and base area
6.2 Plate thickness and gusseted bases
A gusseted/stiffened base transfers force through the shaft, gussets, cleats and welds to the plate. Determine the actual unsupported plate panels from that arrangement. A larger footprint alone does not reduce every panel's bending demand; stiffeners change the support lines.
Machined complete-bearing column ends can transfer direct compression by contact; their attachments still maintain position and transmit moments, shear, tension and erection actions. Without reliable complete bearing, design the attachment for the forces it must transfer. Fully penetrated column-to-plate butt welds can provide the full member force path when properly designed.
6.3 Eccentric pressure and anchor forces
Compression-only pressure changes from trapezoidal to triangular as eccentricity increases.
Transfer horizontal shear through the specified friction, anchors or shear key/lug system. Do not assume that hold-down bolts automatically provide adequate shear resistance. A column splice must transmit all non-bearing force components; if the ends are not prepared for bearing, design the splice for the complete force transfer.
Last-minute recall
- Bearing strength depends on the stated edition and on concrete/bedding strength.
- Uniform-pressure slab-base thickness uses the larger projection as .
- Never accept a negative concrete contact pressure.
- The uniaxial kern boundary is .
- A triangular compression-only block ends at .
- Anchor tension increases the concrete compression resultant.
- Gussets and stiffeners change the plate's unsupported spans.
- Column attachment, anchors and support bearing are separate force-transfer checks.