Signals and basic operations
First identify the time axis, support and amplitude. A time transformation moves every breakpoint; it does not change an ordinary signal's height. Impulses require an additional area factor.
1.1 Elementary signals and impulses
Past papers · EE 2020–2026 (7 papers): 1 question, 1 mark
The unit step is zero for and one for ; its single endpoint value does not affect ordinary CT integrals. In discrete time, for and zero otherwise. The unit sample is one only at .
For a smooth test function , . Do not square a Dirac impulse or assign it ordinary finite energy. For integer , , with no factor; is nonzero only if is an integer.
| Building block | Definition | Useful representation |
|---|---|---|
| Ramp | ||
| Centred rectangle | for , zero outside | |
| Centred triangle | ||
| Finite discrete pulse | One for |
Here is a duration (s), is a positive integer. Rectangle boundary values matter only when a sampling instant or an impulse sits exactly there; then specify them.
1.2 Time operations and symmetry
Past papers · EC 2020–2026 (7 papers): 1 question, 2 marks · EE 2020–2026 (7 papers): 1 question, 2 marks
For , a feature originally at moves to . This breakpoint rule handles reversal, scaling and shifting in one step. reverses the order of features. DT indices must remain integers; interpolation is not implicit in .
Real-even times real-odd integrates to zero on a symmetric interval when integrable. Conjugate symmetry, , is different from even symmetry. A real signal need not be even.
1.3 Periodicity and orthogonality
Past papers · EC 2020–2026 (7 papers): 1 question, 2 marks · EE 2020–2026 (7 papers): 2 questions, 3 marks
A period repeats the entire signal. The fundamental period is the smallest positive period; a constant has no smallest positive CT period. In discrete time, frequencies differing by describe the same complex exponential.
For sums of CT sinusoids, nonzero frequencies must be commensurate for periodicity. For sums of DT periodic signals, the least common multiple of component periods is a period; cancellations may reduce the fundamental period. Sampling a CT periodic signal with rational guarantees period samples; the actual fundamental period can divide . Irrational sampling ratios do not guarantee periodicity, although special signals or sample values can still repeat.
1.4 Energy and average power
Signal energy measures a squared norm. If is voltage, has units V·s and has units V; division by resistance gives physical joules and watts. DT energy has units unless a sampling interval is explicitly included.
Useful checks: with has ; with has . A nonzero-frequency CT cosine of peak has . A unit step has power under the two-sided average above. A DT cosine at or is exceptional: calculate its actual samples instead of automatically dividing by two.
Last-minute recall
- Move breakpoints by solving the transformed argument equal to the old breakpoint.
- CT impulse scaling uses an absolute value; DT impulse scaling does not.
- DT frequencies repeat every .
- A rational frequency ratio gives a DT period; reduce the fraction first.
- Orthogonality depends on the integration interval.
- Energy scales with inverse time compression; power does not.
- A nonzero finite-energy signal has zero average power.