Chapter 1

Signals and basic operations

First identify the time axis, support and amplitude. A time transformation moves every breakpoint; it does not change an ordinary signal's height. Impulses require an additional area factor.

1.1 Elementary signals and impulses

Past papers · EE 2020–2026 (7 papers): 1 question, 1 mark

The unit step u(t)u(t) is zero for t<0t<0 and one for t>0t>0; its single endpoint value does not affect ordinary CT integrals. In discrete time, u[n]=1u[n]=1 for n≥0n\ge0 and zero otherwise. The unit sample δ[n]\delta[n] is one only at n=0n=0.

For a smooth test function vv, ∫v(t)δ′(t−t0)dt=−v′(t0)\int v(t)\delta'(t-t_0)dt=-v'(t_0). Do not square a Dirac impulse or assign it ordinary finite energy. For integer m≠0m\ne0, δ[mn]=δ[n]\delta[mn]=\delta[n], with no 1/∣m∣1/|m| factor; δ[mn−r]\delta[mn-r] is nonzero only if r/mr/m is an integer.

Building blockDefinitionUseful representation
Rampr(t)=tu(t)r(t)=tu(t)r′(t)=u(t)r'(t)=u(t)
Centred rectanglerect⁡(t/T)=1\operatorname{rect}(t/T)=1 for ∣t∣<T/2\vert t\vert <T/2, zero outsideu(t+T/2)−u(t−T/2)u(t+T/2)-u(t-T/2)
Centred triangletri⁡(t/T)=max⁡(1−∣t∣/T,0)\operatorname{tri}(t/T)=\max(1-\vert t\vert /T,0)[r(t+T)−2r(t)+r(t−T)]/T[r(t+T)-2r(t)+r(t-T)]/T
Finite discrete pulseOne for 0≤n<L0\le n<Lu[n]−u[n−L]u[n]-u[n-L]

Here T>0T>0 is a duration (s), LL is a positive integer. Rectangle boundary values matter only when a sampling instant or an impulse sits exactly there; then specify them.

1.2 Time operations and symmetry

Past papers · EC 2020–2026 (7 papers): 1 question, 2 marks · EE 2020–2026 (7 papers): 1 question, 2 marks

For y(t)=Ax(at−b)y(t)=A x(at-b), a feature originally at t=qt=q moves to t=(q+b)/at=(q+b)/a. This breakpoint rule handles reversal, scaling and shifting in one step. a<0a<0 reverses the order of features. DT indices must remain integers; interpolation is not implicit in x[n/2]x[n/2].

Real-even times real-odd integrates to zero on a symmetric interval when integrable. Conjugate symmetry, x(−t)=x∗(t)x(-t)=x^*(t), is different from even symmetry. A real signal need not be even.

1.3 Periodicity and orthogonality

Past papers · EC 2020–2026 (7 papers): 1 question, 2 marks · EE 2020–2026 (7 papers): 2 questions, 3 marks

A period repeats the entire signal. The fundamental period is the smallest positive period; a constant has no smallest positive CT period. In discrete time, frequencies differing by 2π2\pi describe the same complex exponential.

For sums of CT sinusoids, nonzero frequencies must be commensurate for periodicity. For sums of DT periodic signals, the least common multiple of component periods is a period; cancellations may reduce the fundamental period. Sampling a CT periodic signal with Ts/T0=p/qT_s/T_0=p/q rational guarantees period qq samples; the actual fundamental period can divide qq. Irrational sampling ratios do not guarantee periodicity, although special signals or sample values can still repeat.

1.4 Energy and average power

Signal energy measures a squared norm. If xx is voltage, ExE_x has units V2^2·s and PxP_x has units V2^2; division by resistance gives physical joules and watts. DT energy has units [x]2[x]^2 unless a sampling interval is explicitly included.

Useful checks: e−atu(t)e^{-at}u(t) with a>0a>0 has E=1/(2a)E=1/(2a); anu[n]a^nu[n] with ∣a∣<1|a|<1 has E=1/(1−∣a∣2)E=1/(1-|a|^2). A nonzero-frequency CT cosine of peak AA has P=∣A∣2/2P=|A|^2/2. A unit step has power 1/21/2 under the two-sided average above. A DT cosine at Ω=0\Omega=0 or π\pi is exceptional: calculate its actual samples instead of automatically dividing by two.

Last-minute recall

  • Move breakpoints by solving the transformed argument equal to the old breakpoint.
  • CT impulse scaling uses an absolute value; DT impulse scaling does not.
  • DT frequencies repeat every 2π2\pi.
  • A rational frequency ratio gives a DT period; reduce the fraction first.
  • Orthogonality depends on the integration interval.
  • Energy scales with inverse time compression; power does not.
  • A nonzero finite-energy signal has zero average power.

Revise offline: the whole Signals and Systems handbook as one PDF

52 pages · 2.1 MBFree to read online. Sign in to download the PDF.We save the handbook, version and request time in My downloads. Privacy policy

All chapters · Corrections