Chapter 2

LTI systems in time and frequency

Test the system definition before using convolution. The impulse response completely determines a zero-state LTI system, but merely applying an impulse to a nonlinear system does not make convolution valid.

2.1 System-property tests

Past papers · EC 2020–2026 (7 papers): 4 questions, 5 marks · EE 2020–2026 (7 papers): 4 questions, 7 marks

Let T\mathcal T map an input xx to an output yy. Tests must hold for every allowed input and every shift, not just one sinusoid or one impulse.

System formDecision method
y(t)=x(ϕ(t))y(t)=x(\phi(t))Linear; causal only if ϕ(t)≤t\phi(t)\le t throughout the domain; time invariant only for ϕ(t)=t−c\phi(t)=t-c
y(t)=g(t)x(t)y(t)=g(t)x(t)Linear; time invariant if gg is constant; stable if gg is bounded
y(t)=∣x(t)∣y(t)=\vert x(t)\vert or x2(t)x^2(t)Nonlinear, memoryless, causal, time invariant; BIBO stable
Running maximum of ∣x[k]∣\vert x[k]\vert for k≤nk\le nNonlinear, causal and time invariant on the full integer axis; stable
Fixed-lower-limit integral or sumTest the shifted lower limit; linearity does not imply time invariance

These statements assume the input class allows arbitrary values. A nonzero fixed initial condition generally makes the input-output map affine rather than linear. For a well-defined zero-state network, constant linear combinations and cascades of LTI blocks remain LTI; an extra squarer, time multiplier or time scaling can change this.

For a time-varying weighted sum y[n]=∑k=0nckx[k]y[n]=\sum_{k=0}^n c_kx[k], n≥0n\ge0, the bound ∣y[n]∣≤∥x∥∞∑k=0n∣ck∣|y[n]|\le\|x\|_\infty\sum_{k=0}^n|c_k| proves BIBO stability when the absolute partial sums have a uniform finite bound. Thus geometrically decreasing weights with ratio magnitude below one are stable, while unit weights accumulate a bounded step without bound. Do not apply an LTI impulse-response test to a time-varying system.

2.2 Convolution and its shortcuts

Past papers · EC 2020–2026 (7 papers): 3 questions, 4 marks · EE 2020–2026 (7 papers): 6 questions, 8 marks

Flip one signal, shift it by the output time, multiply on the overlap and integrate or sum. For finite supports, write the overlap limits before writing the integrand.

Convolution is commutative, associative and distributive when it exists. Delays add. Differentiation may be placed on either factor: (x∗h)′=x′∗h=x∗h′(x*h)'=x'*h=x*h', under ordinary convergence conditions or distributionally when defined. For causal CT signals use 0≤τ≤t0\le\tau\le t; for causal DT signals use 0≤k≤n0\le k\le n.

If xr(t)=x(−t)x_r(t)=x(-t), then x∗xrx*x_r is even whenever the convolution exists; the same holds for sequences. Reversal alone gives this result even for complex xx. Conjugate reversal instead gives a conjugate-symmetric result.

Overlap of two causal rectangular pulses determines the convolution height.Overlap of two causal rectangular pulses determines the convolution height.

2.3 Impulse response, step response and stability

Past papers · EC 2020–2026 (7 papers): 1 question, 2 marks · EE 2020–2026 (7 papers): 2 questions, 3 marks

Let hh be the zero-state impulse response and gg the response to a unit step. Causality and stability are independent properties.

Memoryless LTI systems have h(t)=Kδ(t)h(t)=K\delta(t) or h[n]=Kδ[n]h[n]=K\delta[n]. An LTI inverse satisfies h∗hinv=δh*h_{\rm inv}=\delta; an inverse need not be causal or stable. Cascade responses convolve and parallel responses add. Finite DT impulse responses with finite coefficients are stable, even if noncausal. ∣h[n]∣<1|h[n]|<1 at each sample does not ensure summability. An integrator h=uh=u is causal but unstable: bounded step input gives a ramp.

2.4 Exponential response and pole geometry

Past papers · EC 2020–2026 (7 papers): 1 question, 2 marks · EE 2020–2026 (7 papers): 3 questions, 5 marks

Complex exponentials are LTI eigenfunctions wherever the defining response integral or sum converges. A stable real LTI system changes the amplitude and phase of an eternal sinusoid but does not create a new frequency.

A proper rational causal CT response is BIBO stable if all uncancelled poles lie strictly in the left half-plane. DT stability and ROC are treated in Chapter 5. Cancellation may hide an internally unstable state; these tests refer to the external zero-state map. Real-coefficient rational functions have nonreal poles and zeros in conjugate pairs.

A CT rational function with zeros at −pi∗-p_i^* corresponding to each pole pip_i has constant magnitude on the imaginary axis, provided there are no poles there. Equal distances prove this all-pass magnitude property; it alone does not establish stability. A causal realisation with a right-half-plane pole is unstable, so evaluating its rational expression at jωj\omega is only a formal frequency-axis calculation, not a convergent Fourier transform of its causal impulse response.

A first-order zero-state equation y˙+ay=bx\dot y+ay=bx gives h(t)=be−atu(t)h(t)=be^{-at}u(t) for a causal system; aa is s−1^{-1} and bb has units [y]/([x] s)[y]/([x]\,\mathrm{s}). The jump h(0+)=bh(0^+)=b follows by integrating the impulse-driven equation through zero.

2.5 Phase delay, group delay and all-pass systemsEC

Past papers · EC 2020–2026 (7 papers): 2 questions, 3 marks

Use a continuous, unwrapped phase ϕ(ω)=∠H(jω)\phi(\omega)=\angle H(j\omega) on a band where H≠0H\ne0. A phase jump at a zero is not a finite group-delay value.

A stable all-pass section reflects each pole to a zero: zi=1/pi∗z_i=1/p_i^* in DT and zi=−pi∗z_i=-p_i^* in CT. A flat magnitude alone does not imply pure delay. A constant phase offset changes phase delay but not group delay. In the distortionless formula KK is a real constant for real signals; for K>0K>0, both delays equal tdt_d. At zero frequency take a limit if it exists.

Last-minute recall

  • One input-output pair can disprove LTI behaviour but cannot establish it.
  • An impulse response determines a system only after LTI is established.
  • Convolution delays add; support endpoints add.
  • Differentiate the step response, including its jumps.
  • Stability uses absolute area or absolute sum.
  • Eternal sinusoidal input gives only the same frequency for a stable LTI system.
  • EC: flat magnitude does not guarantee constant group delay.

Revise offline: the whole Signals and Systems handbook as one PDF