Weirs on permeable foundations
A diversion weir raises river level mainly through its crest; a barrage obtains much of its ponding through gates. The foundation must resist uplift and piping, while the floor and downstream protection must also withstand surface-flow scour.
6.1 Failure modes and creep theories
Piping starts when seepage removes foundation particles, commonly near an unprotected downstream exit. Uplift can lift or rupture the impervious floor. Surface scour can expose a cutoff even when a seepage calculation passes. Design the exit, floor weight, cutoff penetration and scour protection together.
Bligh assumes uniform loss per length of creep; Lane gives greater importance to vertical barriers. Both are empirical. Neither establishes the actual local exit gradient. Khosla uses potential flow through the foundation instead of forcing water to follow the floor contact.
6.2 Uplift-resistant floor thickness
6.3 Khosla end-pile solution
Past papers · CE 2020–2026 (14 papers): 1 question, 1 mark
The elementary solution assumes steady two-dimensional seepage through homogeneous isotropic pervious material extending to great depth, an impervious horizontal floor of negligible thickness, and a thin vertical end cutoff. It is not a universal formula for layered foundations or an arbitrary collection of piles.
A downstream cutoff is especially effective in reducing the exit gradient. An upstream cutoff is useful for reducing uplift under much of the floor. A longer floor reduces head gradient but does not remove the singular unprotected exit as downstream cutoff depth tends to zero. Cutoff bottom level must also be below the relevant scour level.
Khosla elementary downstream cutoff: E at the floor junction, D at the tip, and head fraction zero at the downstream surface.
6.4 Corrections and design sequence
For a complex floor, identify elementary profiles and obtain their key-point heads. Correct for pile interference, actual floor thickness and sloping floor. Corrections are adjustments to head percentages, not extra metres of head. An intermediate pile does not simply contribute twice its depth to an exact potential-flow solution.
Use corrected heads to calculate uplift at the actual underside. Check floor thickness at several stations, not just at a cutoff. Size the downstream pile for both exit gradient and scour; provide filter and launching-apron protection beyond the impervious floor. Scour depth is measured from flood water level, so convert it to a bed/cutoff elevation before comparing depths.
Last-minute recall
- Uplift, piping and surface scour require different checks.
- Count both faces of a thin cutoff in creep length.
- Bligh and Lane coefficients belong to different empirical models.
- A pressure-head difference and a piezometric-level difference give different-looking floor formulas.
- Khosla exit gradient uses the downstream cutoff depth.
- Fractions, percentages and metres of head are three different quantities.
- Correct simple-profile heads before using them for a complex floor.
- A safe exit-gradient calculation does not establish safe cutoff penetration against scour.