Chapter 5

Lined and unlined canals

A rigid lining fixes the boundary geometry; an alluvial channel can adjust by erosion and deposition. Select resistance, sediment and stability relations that match the boundary condition.

5.1 Alignment, lining and hydraulic section

A ridge canal follows a watershed and can command both sides with few cross-drainage works. A contour canal runs approximately along contours and commands the lower side; it crosses drainage lines. A side-slope canal runs across contours on the side slope. Canal falls accommodate terrain drops; escapes discharge excess canal water.

Lining reduces seepage and roughness, controls erosion and may reduce required area. It can suffer cracking and uplift when the canal is emptied while groundwater remains high. Freeboard is above the full-supply water level and is not part of flow area.

5.2 Rounded lined sections

Past papers · CE 2020–2026 (14 papers): 2 questions, 4 marks

The standard rounded triangular design has a circular bottom of radius equal to design water depth, with straight sides tangent to it. Its geometry differs from a sharp V-section even when side slopes match.

5.3 Kennedy and Lacey regime design

Past papers · CE 2020–2026 (14 papers): 1 question, 2 marks

A regime channel conveys its water and sediment without persistent net silting or scouring. Lacey's ideal requires steady discharge, uniform flow, constant sediment grade and concentration, and freely adjustable boundaries of incoherent alluvium. A lined or cohesive channel does not meet these assumptions.

Kennedy design is iterative: choose depth, find Vˉ0\bar V_0, calculate required area from discharge, determine section dimensions, and check the resistance relation and available slope. An additional geometric or slope condition is needed; Kennedy alone does not determine the entire section.

For a wide channel, Pw≈bP_w\approx b and Rh≈yR_h\approx y. Otherwise solve area and perimeter for the actual geometry. Do not replace wetted perimeter by bed width for a narrow section. Sediment load is a mass or volume rate; sediment concentration is load divided by water discharge.

5.4 Tractive-force design

Past papers · CE 2020–2026 (14 papers): 1 question, 2 marks

For sediment-free or low-sediment water, preventing erosion may govern rather than maintaining a sediment regime. Compare the imposed shear with the permitted shear of the boundary material.

5.5 Regulators, outlets and sediment control

A head regulator controls canal entry; a cross regulator on the parent canal raises and controls upstream level. Undersluices maintain a relatively clear approach pocket and pass sediment-laden lower water. A divide wall separates the undersluice pocket from the main weir flow. A silt excluder acts before sediment enters the canal; an ejector removes sediment already in it.

OutletDischarge sensitivity within its working range
Non-modularDepends on both parent and receiving-channel levels
Semi-modularDepends on parent-channel level, independent of receiving level while free flow persists
Modular or rigid moduleIndependent of both levels within specified operating limits

Last-minute recall

  • Use flow depth, excluding freeboard, in area and perimeter.
  • Manning slope equals bed slope only for uniform flow.
  • Rounded-bottom geometry is not sharp triangular geometry.
  • Kennedy's critical velocity concerns sediment, not Froude number.
  • Lacey constants require metric discharge and grain size in mm.
  • Mean shear is γwRhSf\gamma_wR_hS_f; wide-channel bed shear uses depth.
  • Upstream silt exclusion and downstream silt ejection are different operations.
  • Outlet setting depends on both rating exponents.

Revise offline: the whole Irrigation Engineering handbook as one PDF

48 pages · 2.0 MBFree to read online. Sign in to download the PDF.We save the handbook, version and request time in My downloads. Privacy policy

All chapters · Corrections