Chapter 4

Streamflow measurement and records

Discharge needs both a flow area and representative velocity, or a calibrated hydraulic/tracer relation. A stage record becomes a discharge record only through a valid rating for the prevailing control.

4.1 Velocity–area measurements

Past papers · CE 2020–2026 (14 papers): 1 question, 2 marks

Staff gauges read water-surface elevation relative to a local datum; float, pressure, bubble and radar instruments can record stage continuously. Mechanical current meters infer speed from revolutions; acoustic Doppler instruments sample velocity using frequency shifts.

For mid-section measurements, a vertical represents the width halfway to each adjacent vertical. Treat banks and edge strips using the actual boundary geometry. If instead using mean-section panels between verticals, panel discharge is panel width times mean depth times mean velocity; do not mix the two conventions midway through a calculation. A surface float needs a calibrated surface-to-mean velocity factor; do not assume its speed is the depth average.

4.2 Rating curves and indirect measurement

A stable control gives a repeatable stage–discharge relation. Bed scour, vegetation, tidal effects or downstream backwater can change it. In an unsteady flood, rising and falling limbs may have different discharges at the same stage: the rating can form a loop.

Slope–area measurement estimates a past flood using high-water marks, cross-sections and hydraulic roughness. Weirs/flumes infer discharge from measured head with a calibrated control relation. Manning’s conveyance, energy losses and measuring-structure formulas: see the Hydraulics handbook. Neither a single stage nor a single surface velocity is sufficient at a site with an unknown rating.

4.3 Dilution gauging

Tracer dilution is useful where a rough, turbulent reach mixes well but point-velocity measurement is difficult. Require full mixing across the section, tracer conservation, background correction and approximately steady discharge during sampling.

4.4 Flow duration and cumulative yield

A flow-duration curve orders discharges from large to small and plots exceedance percentage. It discards chronology. A flow mass curve retains chronology and plots accumulated volume; its slope is discharge. Reservoir sizing requires the latter or the original time series.

Naturalised flow reverses artificial diversions, storage changes, reservoir evaporation increments and return flows using a water balance. Add net abstractions back to observed flow and subtract artificial return additions; count each transfer once.

Last-minute recall

  • Velocity sampling depths are measured below the surface.
  • Two-point averaging uses 0.2 and 0.8 of depth.
  • Multiply each strip’s area by its own mean speed before summing.
  • A rating’s zero-flow stage need not be zero gauge reading.
  • Tracer calculations require complete mixing and mass conservation.
  • A duration curve loses the time order; a mass curve preserves it.

Revise offline: the whole Hydrology handbook as one PDF