Discharge needs both a flow area and representative velocity, or a calibrated hydraulic/tracer relation. A stage record becomes a discharge record only through a valid rating for the prevailing control.
4.1 Velocity–area measurements
Past papers · CE 2020–2026 (14 papers): 1 question, 2 marks
Staff gauges read water-surface elevation relative to a local datum; float, pressure, bubble and radar instruments can record stage continuously. Mechanical current meters infer speed from revolutions; acoustic Doppler instruments sample velocity using frequency shifts.
For mid-section measurements, a vertical represents the width halfway to each adjacent vertical. Treat banks and edge strips using the actual boundary geometry. If instead using mean-section panels between verticals, panel discharge is panel width times mean depth times mean velocity; do not mix the two conventions midway through a calculation. A surface float needs a calibrated surface-to-mean velocity factor; do not assume its speed is the depth average.
4.2 Rating curves and indirect measurement
A stable control gives a repeatable stage–discharge relation. Bed scour, vegetation, tidal effects or downstream backwater can change it. In an unsteady flood, rising and falling limbs may have different discharges at the same stage: the rating can form a loop.
Slope–area measurement estimates a past flood using high-water marks, cross-sections and hydraulic roughness. Weirs/flumes infer discharge from measured head with a calibrated control relation. Manning’s conveyance, energy losses and measuring-structure formulas: see the Hydraulics handbook. Neither a single stage nor a single surface velocity is sufficient at a site with an unknown rating.
4.3 Dilution gauging
Tracer dilution is useful where a rough, turbulent reach mixes well but point-velocity measurement is difficult. Require full mixing across the section, tracer conservation, background correction and approximately steady discharge during sampling.
4.4 Flow duration and cumulative yield
A flow-duration curve orders discharges from large to small and plots exceedance percentage. It discards chronology. A flow mass curve retains chronology and plots accumulated volume; its slope is discharge. Reservoir sizing requires the latter or the original time series.
Naturalised flow reverses artificial diversions, storage changes, reservoir evaporation increments and return flows using a water balance. Add net abstractions back to observed flow and subtract artificial return additions; count each transfer once.
Last-minute recall
- Velocity sampling depths are measured below the surface.
- Two-point averaging uses 0.2 and 0.8 of depth.
- Multiply each strip’s area by its own mean speed before summing.
- A rating’s zero-flow stage need not be zero gauge reading.
- Tracer calculations require complete mixing and mass conservation.
- A duration curve loses the time order; a mass curve preserves it.