Chapter 7

Reservoir capacity and flood routing

Conservation storage carries water through deficits; flood storage temporarily absorbs excess inflow. Both use continuity, but a routing calculation also needs a storage–outflow relation and a time step.

7.1 Storage capacity from chronological records

Dead storage lies below the normal usable outlet level. Live storage is the usable volume between minimum drawdown and full reservoir levels; surcharge storage lies above the normal full level during a flood. Distinguish allocated conservation, flood-control and sediment volumes in the stated operating policy.

On a cumulative inflow (mass) curve, draw demand lines of the appropriate slope. The largest accumulated demand-minus-inflow deficit over a critical dry period is the active capacity. It is not always the full range of the unreset cumulative difference: surplus water may spill.

7.2 Storage geometry and sediment allowance

An elevation–area curve becomes an elevation–storage curve by integration. Sedimentation reduces usable storage; a constant-rate life estimate is only an approximation because sediment input and trapping can change.

7.3 Level-pool reservoir routing

Past papers · CE 2020–2026 (14 papers): 1 question, 2 marks

Hydrologic routing combines lumped continuity with a storage relation. For a level pool, storage depends on elevation. An uncontrolled fixed outlet also makes outflow a single-valued function of elevation, permitting a storage–outflow table.

For an uncontrolled reservoir with monotonically increasing outflow versus storage, maximum outflow and maximum storage occur when I=OI=O as inflow crosses below outflow. This need not hold for gate-controlled releases. Hydraulic routing instead solves distributed continuity and momentum; the method of characteristics is a hydraulic-routing method.

7.4 Muskingum channel routing

Past papers · CE 2020–2026 (14 papers): 1 question, 1 mark

A channel reach can have different storage for the same outflow on its rising and falling limbs. Muskingum approximates storage by a weighted combination of inflow and outflow. It is a hydrologic channel-routing model, not a momentum-equation solution.

Prism storage is KrouteOK_{\rm route}O; wedge storage is Kroutex(I−O)K_{\rm route}x(I-O), positive on a rising wave and negative on a falling wave. At x=0x=0, storage depends only on outflow and the model is a linear reservoir. At x=0.5x=0.5 and Δt=Kroute\Delta t=K_{\rm route} the recurrence gives O2=I1O_2=I_1, a pure one-step translation. If observed reach data are given, integrate I−OI-O to estimate storage change, then seek xx for which storage versus xI+(1−x)OxI+(1-x)O is close to linear; the slope estimates KrouteK_{\rm route}.

7.5 Translation and linear-reservoir attenuation

Translation delays a hydrograph without changing its shape. Storage attenuation smooths it. Simple surface-runoff models often combine these mechanisms after converting rainfall to excess.

Last-minute recall

  • Size active storage from chronological deficits, allowing surplus to spill.
  • Add dead storage and other allocations only as specified.
  • Convert discharge to interval volume before computing capacity.
  • Modified Puls uses a single-valued storage–outflow relation for its standard form.
  • Reservoir peak outflow equals inflow only under the stated fixed-outlet conditions.
  • Muskingum coefficients must sum to one.
  • Use consistent time units in routing and storage.
  • Pure translation preserves peak; storage generally attenuates it.