Use energy balances to relate stream temperatures before applying LMTD or effectiveness. LMTD is convenient when terminal temperatures are known. The effectiveness–NTU method is convenient when inlet conditions and exchanger size are known but outlet temperatures are not.
7.1 Capacity rates and overall resistance
Past papers · ME 2020–2026 (10 papers): 5 questions, 9 marks
Assume steady operation, negligible heat loss to surroundings, negligible axial conduction, and no work. Hot and cold stream heat rates then have equal magnitudes.
For isothermal phase change, use Q˙=m˙pchfg on that side. Its effective heat-capacity rate tends to infinity; the other stream supplies Cmin. This does not mean its mass flow is infinite.
7.2 LMTD and terminal differences
Past papers · ME 2020–2026 (10 papers): 1 question, 1 mark
The logarithmic mean follows from integrating the local temperature driving force for constant U and constant single-phase capacity rates (or an isothermal phase-changing stream). Pair temperatures that occur at the same physical end of the exchanger.
Flow arrangement
ΔT1
ΔT2
Parallel
Th,i−Tc,i
Th,o−Tc,o
Counterflow
Th,i−Tc,o
Th,o−Tc,i
Use a correction factor for multipass or crossflow arrangements: Q˙=UAFΔTlm,counter, where dimensionless F≤1 comes from the applicable arrangement chart or relation. A supplied chart may use its own temperature-ratio definitions; check them before reading F.
Counterflow terminal differences pair temperatures at the same physical end.
7.3 Effectiveness–NTU relations
Past papers · ME 2020–2026 (10 papers): 1 question, 2 marks
Calculate the capacity-rate ratio with the smaller rate in the numerator. The formulas below use an exchanger with constant overall conductance and capacity rates.
7.4 Other arrangements and performance checks
Use the flow arrangement actually shown. “Crossflow” is incomplete unless the mixing condition of each fluid is identified.
Last-minute recall
Start with the energy balance on both streams.
C=m˙cp is in W/K, not J/K.
Maximum duty uses the inlet-to-inlet temperature difference.
Pair terminal differences according to physical ends.
Equal terminal differences give a finite LMTD by a limit.
Isothermal phase change gives Cr=0.
Use the separate counterflow expression when Cr=1.
Identify mixing before using a crossflow formula.
Fouling increases resistance and reduces U on the same area basis.
Revise offline: the whole Heat Transfer handbook as one PDF
50 pages · 1.9 MBFree to read online. Sign in to download the PDF.We save the handbook, version and request time in My downloads. Privacy policy