Water quality and measurement
A concentration needs a chemical basis as well as a unit. Begin with mass, charge and equivalents; then distinguish a laboratory measurement from a drinking-water limit or a composite index.
1.1 Concentration and solids measurements
Past papers · CE 2020–2026 (14 papers): 1 question, 2 marks
Turbidity measures light scattering, commonly by nephelometry in NTU; it is not a mass concentration. True colour excludes suspended matter; apparent colour includes it. Taste, odour and temperature affect acceptability. Electrical conductivity indicates ionic content but has no universal conversion to total dissolved solids (TDS).
Filtration separates operationally defined suspended and dissolved fractions. Drying measures residue; subsequent ignition measures loss on ignition. Volatile solids approximate organic solids but are not identical to them: some inorganic matter volatilises and some organic carbon can remain. Use the test temperatures and masses specified in the question. Settleable solids are commonly measured by an Imhoff cone in mL/L.
1.2 Acids, bases and aqueous speciation
Past papers · CE 2020–2026 (14 papers): 4 questions, 7 marks
Square brackets below denote molar concentrations. Concentration-based equilibrium formulas approximate activity-based relations in dilute water. pH is logarithmic; never average pH values to mix two waters.
For ammonium/ammonia, use the pair NH₄⁺/NH₃: below at 25 °C, NH₄⁺ predominates; both species remain present. For carbonate buffering, use . The corresponding constants depend on temperature and ionic strength.
1.3 Hardness and equivalent concentrations
Past papers · CE 2020–2026 (14 papers): 5 questions, 8 marks
Hardness is mainly due to Ca²⁺ and Mg²⁺; include other reported polyvalent hardness-producing cations, such as Fe²⁺, if specified. Na⁺ and K⁺ do not cause hardness. Non-carbonate salts can contribute both hardness and TDS, but the two quantities are not interchangeable.
EDTA complexes Ca²⁺ and Mg²⁺ in a 1:1 molar ratio. Total-hardness titration uses an approximately pH-10 buffer and eriochrome black T: wine red changes to blue at the endpoint.
1.4 Alkalinity and titration endpoints
Past papers · CE 2020–2026 (14 papers): 1 question, 2 marks
Alkalinity is acid-neutralising capacity, not pH. High-pH water need not have high buffering capacity. Phenolphthalein alkalinity reaches about pH 8.3; total alkalinity reaches the specified endpoint near pH 4.5.
For the conventional OH⁻/CO₃²⁻/HCO₃⁻ system, neglect H⁺ and assume OH⁻ and HCO₃⁻ do not coexist appreciably. Each table entry is an alkalinity contribution in mg/L as CaCO₃, not an ion concentration.
| Titration result | OH⁻ contribution | CO₃²⁻ contribution | HCO₃⁻ contribution |
|---|---|---|---|
| 0 | 0 | ||
| 0 | |||
| 0 | 0 | ||
| 0 | |||
| 0 | 0 |
1.5 Biological indicators and pathogens
Past papers · CE 2020–2026 (14 papers): 2 questions, 3 marks
Indicator bacteria reveal possible faecal contamination; their absence does not prove the absence of every pathogen. Membrane filtration counts colonies; multiple-tube fermentation estimates the most probable number (MPN) statistically. Presumptive, confirmed and completed tests are stages of the conventional coliform procedure.
| Group | Important water-related examples | Revision point |
|---|---|---|
| Bacteria | Cholera, typhoid, bacillary dysentery | Coliforms are indicators, not the cause of every listed disease |
| Viruses | Poliomyelitis, hepatitis A/E | Infectious hepatitis in conventional questions refers to viral disease |
| Protozoa | Giardia, Cryptosporidium, amoebic dysentery | Resistant cysts/oocysts need effective barriers |
| Helminths | Guinea-worm disease | Filtration can interrupt water-mediated transmission |
1.6 Drinking-water standards
IS 10500:2012, Drinking Water—Specification, second revision, is listed in the BIS programme of work as reaffirmed in August 2023 with four amendments. “Permissible” below means only in the absence of an alternative source. It is not the normal treatment target. NR means no relaxation.
| Parameter and basis | Acceptable | Permissible |
|---|---|---|
| pH | 6.5–8.5 | NR |
| Turbidity, NTU | 1 | 5 |
| Colour, Hazen units | 5 | 15 |
| TDS, mg/L | 500 | 2000 |
| Total hardness, as CaCO₃, mg/L | 200 | 600 |
| Total alkalinity, as CaCO₃, mg/L | 200 | 600 |
| Chloride, as Cl⁻, mg/L | 250 | 1000 |
| Sulphate, as SO₄²⁻, mg/L | 200 | 400 |
| Nitrate, as NO₃⁻, mg/L | 45 | NR |
| Fluoride, as F, mg/L | 1.0 | 1.5 |
| Iron, as Fe, mg/L | 1.0 | NR |
| Total arsenic, as As, mg/L | 0.01 | NR |
| E. coli/thermotolerant coliforms | Not detectable in 100 mL | NR |
| Total coliforms in treated drinking water | Not detectable in 100 mL | NR |
The updated values are reproduced in the Jal Jeevan Mission monitoring framework; colour is also tabulated in JJM's October 2022 bulletin. Excess fluoride causes fluorosis; nitrate can cause infant methaemoglobinaemia. Lead, arsenic and other toxic contaminants need separate checks even when the water is clear.
1.7 Water quality index
A WQI compresses several measurements into one number. There is no single universal WQI formula, parameter list or grading scale. A weighted arithmetic pollution index usually increases as quality deteriorates; an NSF-style quality score usually increases as quality improves. Never transfer category boundaries between them.
Weights and ratings are method inputs, not universal constants. An aggregate score cannot certify compliance with every individual limit or microbiological requirement.
Last-minute recall
- State whether concentration means ion mass, compound mass, as N, as O₂ or as CaCO₃.
- One meq/L corresponds to 50 mg/L as CaCO₃.
- CH is the smaller of conventional alkalinity and TH; NCH is the remainder.
- Alkalinity consumes acid; pH measures hydrogen-ion activity.
- EDTA/EBT endpoint: wine red to blue.
- MPN tables require dilution-volume correction.
- Turbidity is not TSS and volatile solids are not exactly organic solids.
- WQI weights, rating direction and categories belong to a particular method.