Chapter 1

Single-phase transformers

A transformer exchanges AC power through mutual flux without changing frequency. Start by choosing the referred side; then keep voltage, current, impedance and rating on that side. The circuit separates excitation current from load current.

1.1 Emf, ratio and polarity

Past papers · EE 2020–2026 (7 papers): 2 questions, 3 marks

N1,N2N_1,N_2 are winding turns, Φm\Phi_m is maximum mutual flux (Wb), ff is frequency (Hz), and nt=N1/N2n_t=N_1/N_2 is the turns ratio. Voltage references run from dotted to undotted ends. Primary current enters its dot; secondary load current leaves its dot.

With one end of each winding joined, the voltage between the free ends is the phasor sum or difference according to polarity. For in-phase windings, joining like-polarity ends gives ∣E1−E2∣|E_1-E_2|; joining unlike ends gives E1+E2E_1+E_2. Use a reduced test voltage.

A winding linking several core limbs responds to the signed sum of linked fluxes. Sum the relevant flux phasors with the winding senses before multiplying by turns and frequency. Balanced limb fluxes can sum to zero; the drawing determines which fluxes are linked.

1.2 Equivalent circuit and phasor construction

Past papers · EE 2020–2026 (7 papers): 1 question, 2 marks

R1,X1R_1,X_1 and R2,X2R_2,X_2 are winding resistances and leakage reactances (Ω). The shunt branch represents core-loss resistance RcR_c and magnetising reactance XmX_m (Ω), across the mutual-flux emf E‾1\underline E_1. Its current is I‾0\underline I_0.

To construct a loaded phasor diagram, put V‾2\underline V_2 on the real axis; place I‾2\underline I_2 at −ϕ-\phi for lagging load or +ϕ+\phi for leading load. Add R2I‾2R_2\underline I_2 parallel to current and jX2I‾2jX_2\underline I_2 90° ahead of current to obtain E‾2\underline E_2. Scale to E‾1\underline E_1, add I‾0\underline I_0 to referred load current, then add primary drops. Flux lags the internal voltage drop E‾1\underline E_1 by 90° for a lossless magnetising branch.

An original secondary-side lagging-load phasor construction; arrows add head to tail.An original secondary-side lagging-load phasor construction; arrows add head to tail.

For a linear core, use Lself=Lm+Lℓ=N2/Rm+Xℓ/(2πf)L_{\rm self}=L_m+L_\ell=N^2/\mathcal R_m+X_\ell/(2\pi f): Rm\mathcal R_m is mutual-path reluctance (A/Wb), Lm,LℓL_m,L_\ell magnetising/leakage inductance (H), and XℓX_\ell leakage reactance (Ω). Magnetic-circuit evaluation of reluctance and linked flux is an applied prerequisite; see the Electromagnetic Fields and Waves handbook. Do not infer total self-inductance from leakage reactance alone.

1.3 Open-circuit and short-circuit tests

In the OC test one winding is open and the other receives rated voltage at rated frequency. LV excitation is convenient, not mandatory. In the SC test one winding is shorted and the other receives enough reduced voltage to circulate the specified current; HV excitation is usual. Every result belongs to the instrumented side.

1.4 Voltage regulation

Keep primary voltage and frequency fixed. Define regulation using loaded secondary voltage VV as denominator; some questions instead specify rated voltage. EE below is the no-load secondary voltage in the approximate referred circuit, II is loaded current, and R,XR,X are equivalent series parameters on that side.

For the first-order expression, maximum positive regulation occurs at tan⁡ϕ=X/R\tan\phi=X/R. Approximate zero regulation on leading load satisfies tan⁡∣ϕ∣=R/X\tan|\phi|=R/X. For the exact series expression, zero regulation instead requires 2VI(Rcos⁡ϕ+Xsin⁡ϕ)+I2(R2+X2)=02VI(R\cos\phi+X\sin\phi)+I^2(R^2+X^2)=0.

1.5 Efficiency and daily energy

SNS_N is rated apparent power (VA), xx is the fraction of rated current at approximately rated voltage, cos⁡ϕ\cos\phi is load power factor, PcP_c is constant core loss (W), and Pcu,NP_{\rm cu,N} is rated winding copper loss (W).

1.6 Rating, flux and per-unit quantities

Past papers · EE 2020–2026 (7 papers): 1 question, 1 mark

Heating from copper loss limits current; insulation and core flux constrain voltage and frequency. The kVA rating does not assume a particular load power factor. Reduced voltage does not allow increased winding current unless a new thermal rating is provided.

For core cross-sectional area AcoreA_{\rm core} (m²), Bm=Φm/AcoreB_m=\Phi_m/A_{\rm core}; sinusoidal design requires N≥V/(4.44fBallowedAcore)N\ge V/(4.44fB_{\rm allowed}A_{\rm core}) when winding drop is negligible. BallowedB_{\rm allowed} is the allowed peak flux density (T); convert mm² to m² using 10−610^{-6}. Rated-current SC voltage in pu equals series impedance magnitude in pu. With a stiff source, approximate short-circuit current at rated voltage is rated current divided by ∣Zpu∣|Z_{\rm pu}|. On a new frequency, reactance scales with frequency; resistance does not simply scale that way. Switching near a supply-voltage zero can produce a large transient flux offset and inrush; residual flux and saturation matter.

Last-minute recall

  • Emf uses peak flux and RMS voltage; 4.44 assumes sinusoidal flux.
  • Impedance referral uses the square of the turns ratio.
  • OC gives the shunt branch; SC gives the series branch.
  • Keep OC and SC results on their measured sides until referral.
  • Signed load angle makes the regulation formula work for lead and lag.
  • Maximum efficiency requires copper loss equal to constant loss.
  • All-day efficiency compares energy, including idle energised hours.
  • Core flux follows V/fV/f; winding current still limits kVA.