Chapter 5

Power, energy and power factor

A wattmeter responds to the mean product of the signals applied to its coils. Read the connections and terminal polarities before using a memorised three-phase formula. Real-power sums remain useful even when the load is unbalanced.

5.1 Wattmeter response and power factor

Past papers · EE 2020–2026 (7 papers): 1 question, 2 marks

Current enters the marked current-coil terminal; voltage is marked pressure-coil terminal minus its other terminal. Reversing either coil reverses the reading; reversing both preserves it.

5.2 Connection and pressure-coil errors

Choose whether the wattmeter includes pressure-circuit power or current-coil copper loss. Neither can be removed by changing only the reading sign.

5.3 Three-voltmeter and three-ammeter methods

Past papers · EE 2020–2026 (7 papers): 1 question, 2 marks

Use a known noninductive resistor. The methods infer a cross-product from three magnitude measurements, so their uncertainty can be large when squared quantities nearly cancel.

5.4 Two-wattmeter method and Blondel's theorem

For a three-wire system, use current coils in lines a,ca,c and voltage coils ab,cbab,cb respectively. Call the readings Wa,WcW_a,W_c. Currents flow towards the load. For balanced positive-sequence abcabc, choose VanV_{an} at 0∘0^\circ.

Two-wattmeter terminal convention: line b is the common voltage reference.Two-wattmeter terminal convention: line b is the common voltage reference.

Balanced consuming loadReadings under this convention
Unity power factorEqual positive readings
0.5 laggingWa=0W_a=0, Wc>0W_c>0
Below 0.5 laggingWa<0W_a<0, Wc>0W_c>0
0.5 leadingWc=0W_c=0, Wa>0W_a>0
Purely reactiveEqual magnitudes, opposite signs

5.5 Other three-phase connections and power-factor meters

Past papers · EE 2020–2026 (7 papers): 1 question, 2 marks

For any unfamiliar circuit, identify the actual voltage and current phasors in each wattmeter. A balanced-source label does not imply a balanced load. Solve the load currents first; then take the real part of each coil-voltage/current product.

5.6 Energy meters and meter constants

An induction meter uses a current flux and an approximately quadrature voltage flux to drive a disc. Braking torque rises with speed; steady speed is proportional to active power. Integration of revolutions measures energy. Induction operation requires AC.

5.7 Induction-meter adjustments

Light-load friction causes under-registration; compensation supplies a small driving torque. Excess compensation can cause creeping: slow motion at no load with the voltage coil energised. Holes or slots in the disc interrupt creeping torque. Phase adjustment makes the pressure flux lag the applied voltage by about 90∘90^\circ.

Last-minute recall

  • A wattmeter reads the product of its own coil signals.
  • Reversing one coil changes the reading sign.
  • Subtract included meter losses before reporting load power.
  • Three-meter methods lose accuracy when squared readings nearly cancel.
  • The two-wattmeter sum works for unbalanced three-wire loads.
  • Its reactive-power difference needs balance, sine waves and known sequence.
  • True power factor includes distortion effects.
  • Meter constants may be count per energy or energy per count.
  • Induction-meter positive energy error means fast registration.